A Single-Laser TDLAS Sensor with Dual-Gas Modulation and BiLSTM-Based Spectral Decoupling for CH₄ /C₂ H₆ Detection
Ru jia Wang, Haifeng Qiu, Bairan Song, He Zhang, Yingtian Xu, YunPing Lan, Jilong Tang, Zhipeng Wei
Changchun University of Science and Technology
Key points
From the paper's conclusion- These results confirm that the combined TDLAS–BiLSTM system significantly improves measurement precision and reliability in dual-gas sensing.
Abstract
Tunable Diode Laser Absorption Spectroscopy (TDLAS) is widely used in trace gas detection because of its high sensitivity and selectivity. However, two persistent challenges restrict its performance in multigas applications: spectral cross-interference and harmonic imbalance. These problems are particularly evident for methane (CH 4 ) and ethane (C 2 H 6 ), which commonly coexist in natural gas and atmospheric environments and exhibit overlapping absorption features near 1680 nm. In this study, a single-laser TDLAS detection system is developed by integrating a dual-gas modulation strategy with a Bidirectional Long Short-Term Memory (BiLSTM)-based spectral decoupling approach. The proposed modulation scheme dynamically alternates harmonic responses to match the full width at half-maximum (FWHM) of CH 4 and C 2 H 6, effectively eliminating the harmonic mismatch that limits simultaneous detection in conventional single-amplitude systems. The BiLSTM model further compensates for the cross-interference caused by the spectral overlap of CH 4 and C 2 H 6, thereby enhancing both the accuracy and stability of concentration estimation. During a 200 s stability test, the proposed method maintained consistent performance, yielding standard deviations of 3.66 ppm for 1000 ppm of CH 4 and 0.56 ppm for 100 ppm of C 2 H 6 . The predicted CH 4 and C 2 H 6 concentrations align closely with the reference values, achieving R 2 values of 0.99097 and 0.99819, respectively. These results confirm that the combined TDLAS–BiLSTM system significantly improves measurement precision and reliability in dual-gas sensing. Overall, this approach provides a practical and robust solution for accurate concentration retrieval under cross-sensitivity conditions and offers an effective strategy for multicomponent gas analysis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Highly Sensitive CH4/C2H2 Dual-Component TDLAS Sensor Based on a Dual-Channel Hexagram Multi-Pass CellSensors · 2026
- Baseline-Free Wide-Range Methane Concentration Measurement Based on Logarithmic Second Derivative Spectroscopy.Analytical chemistry · 2026
- CH₄ concentration prediction in WMS-TDLAS systems using 2f/1f signal and CNN.Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy · 2026
- Deep Learning-Enhanced Dual-Component Gas Sensor Based on Wavelength Modulation SpectroscopyAnalytical Chemistry · 2025
- Simplified Calibration and Laser Nonlinearity Error Analysis for Peak-Locking TDLAS SystemsPhotonics · 2026
- Attention-Enhanced CNN–Transformer for Direct and Interpretable Nitrous Oxide Retrieval from Noisy TDLAS SpectraPhotonics · 2026