Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy

Physics-guided spectral attention for baseline-free concentration regression from laser absorption spectra.

Lingran Han, Ying He, Kun You, Aoxue Cai, Wenqing Liu, Bo Wei, Yujun Zhang

Key Laboratory of Environmental Optics & Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China; University of Science and Technology of China, Hefei 230026, China. · Key Laboratory of Environmental Optics & Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China.

Key points

From the paper's conclusion
  • These results demonstrate that the proposed model provides an effective chemometric modeling strategy for quantitative analysis of laser absorption spectra under complex background interference.

Abstract

Tunable diode laser absorption spectroscopy (TDLAS) is widely used for quantitative trace gas analysis. However, direct concentration regression from raw transmitted-intensity spectra remains challenging because weak absorption signals are entangled with baselines, optical-intensity fluctuations, and photodetector noise. Conventional absorbance-based inversion methods rely on baseline extraction and may introduce distortions, while end-to-end models often treat spectra as ordinary one-dimensional sequences and insufficiently account for the multiplicative coupling between optical background and gas absorption. To address this problem, this paper proposes a physics-guided dual-perspective spectral attention network for path-integrated concentration regression directly from raw TDLAS transmitted-intensity spectra without explicit baseline fitting or absorbance conversion. A physics-guided feature enhancement module introduces a second-derivative correlation prior into attention scores, while representative spectral cross-attention retrieves similar patterns using representative spectra selected from the training set. Experiments on concentration-disjoint methane and nitrous oxide datasets show that the proposed model achieves RMSE = 5.1708 ± 1.2274 and R2 = 0.9993 ± 0.0003 on methane, reducing RMSE by 24.2% compared with the strongest Transformer baseline. On nitrous oxide, it achieves RMSE = 3.5669 ± 0.6032 and R2 = 0.9947 ± 0.0045, reducing RMSE by 9.1% compared with the strongest CNN baseline. These results demonstrate that the proposed model provides an effective chemometric modeling strategy for quantitative analysis of laser absorption spectra under complex background interference.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers