Effect of Carbon-Fiber Negative Air Ionization (NAI) on Air Sampled in a Pediatric Hospital: Culturable Airborne Bacteria, Species Diversity, and Biofilm Formation.
Irena Arandjelović, Stefan Mijatović, Andjelija Ilić, Jelena Trajković, Jelena Antić Stanković, Borko Gobeljić, Aleksandar Sovtić, Mihail Baša,
Institute of Microbiology and Immunology, Faculty of Medicine, University of Belgrade, 11000 Belgrade, Serbia. · Institute of Physics Belgrade, University of Belgrade, Pregrevica 118, 11000 Belgrade, Serbia.
Key points
From the paper's conclusion- Overall, bacterial counts were 1.37–6.13-fold higher in NTASs than in ITASs across isolated species, indicating a substantial reduction in culturable airborne bacteria following NAI treatment.
Abstract
Bioaerosols in hospital air pose a threat of respiratory infections, particularly among immunocompromised patients. Abating their effects by diverse methods proposed for air purification remains an open topic. In particular, low environmental bioaerosol concentrations, alongside species diversity, make such studies more difficult. We designed environmental indoor air samplers aimed at: (i) direct collection and quantification of culturable airborne bacteria from a selected location and (ii) accurate evaluation of effects of negative air ions (NAIs) on airborne bacteria. We studied ion-bioaerosol interaction in three distinct pediatric hospital departments by collecting non-treated (NTAS) and ion-treated (ITAS) samples side by side. Air was sampled at 0.5 m/s for 90 min (68.7 m3), with airborne bacteria collected directly onto chromogenic media. NTASs were dominated by Micrococcus luteus (58.27%), Staphylococcus hominis (15.56%), and S. haemolyticus (10.37%). ITASs were dominated by M. luteus (38.73%), S. haemolyticus (20.42%), S. hominis (12.68%), and S. warneri (11.27%). Overall, bacterial counts were 1.37-6.13-fold higher in NTASs than in ITASs across isolated species, indicating a substantial reduction in culturable airborne bacteria following NAI treatment. These findings show the promise of carbon-fiber-based NAI technology as a complementary approach to improving hospital air quality and reducing airborne bacterial contamination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Can isolated negative-pressure devices reduce transmission of respiratory infection in critical care units: A laboratory-based controlled experimental observational study.Journal of infection prevention · 2026
- An Improved Protocol for Indoor Airborne Bacterial Enumeration and Elimination Using a Cold- Plasma Air Sanitizer: A pilot studyInternational Journal of Applied Technology in Medical Sciences · 2026
- Spatiotemporal Contamination Characteristics, Bacterial Community Structure, and Airflow-Mediated Transport of Bacterial Aerosols in a Pediatric Emergency Consulting Room.Environmental research · 2026
- Air disinfection effect of different disinfection methods in high-risk healthcare spaces.Photochemistry and photobiology · 2026
- Developing a sensitive indoor air surveillance approach for nosocomial pathogens and antimicrobial resistancebioRxiv · 2026
- Leveraging zeta potential as a surface charge metric for trapping and killing of airborne bacteriaScientific Reports · 2026