An Improved Protocol for Indoor Airborne Bacterial Enumeration and Elimination Using a Cold- Plasma Air Sanitizer: A pilot study
Mohammed Ibrahim Saeed, Ahmed Luay Osman, Abdelgadir Alamin Altoum, Salah-Eldin Omar Hussein, Salma Elnour
Gulf Medical University
Key points
From the paper's conclusion- Objectives: This study evaluated the efficacy of a cold-plasma air sanitizer in reducing airborne bacterial contamination and developed a standardized protocol for bacterial enumeration in indoor air samples.
Abstract
Airborne bacteria pose significant health risks in indoor environments, particularly for immunocompromised individuals. Air sanitizers represent a promising intervention for reducing microbial contamination in enclosed spaces. Objectives: This study evaluated the efficacy of a cold-plasma air sanitizer in reducing airborne bacterial contamination and developed a standardized protocol for bacterial enumeration in indoor air samples. Methods: Air samples (500 L per sample) were collected using a Sugold FX-100ST microbial air sampler (flow rate 100 L/min for 5 minutes) from microbiology and hematology teaching laboratories (1000 m³ room volume) at Gulf Medical University. Samples were collected immediately before sanitizer activation (baseline) and at 30-minute intervals during cold-plasma treatment (TPA Air Technology, Germany) for 24 hours. Samples were directly inoculated onto Chocolate agar, CLED agar, and Chromogenic UTI agar and incubated at 37°C for 24-48 hours. Total airborne particle counts (0.3-10 μm) were measured using an Atmotech particle counter. Experiments were performed in triplicate on three separate days (n=9 per time point). Bacterial identification was performed using Gram staining and biochemical tests. Statistical analysis employed paired t-tests and one-way ANOVA (p<0.05). Results: Significant bacterial reductions were observed following sanitizer activation. Baseline bacterial concentrations were 75.4±12.3 CFU/500L on Chocolate agar, 59.2±10.8 CFU/500L on CLED agar, and 26.4±6.7 CFU/500L on Chromogenic agar. Mean reduction rates at 24 hours were 94.7%, 96.5%, and 96.1%, respectively. Predominant organisms were Micrococcus spp. (62%) and Bacillus spp. (28%). Coagulase-positive Staphylococcus aureus (n=2) and Gram-negative species including Burkholderia cepacia and Stenotrophomonas maltophilia were also isolated. Strong positive correlation was observed between particle counts and bacterial concentrations (r=0.89, p<0.001). Conclusion: Cold-plasma air sanitization effectively reduced airborne bacteria by >90% within 24 hours. The standardized enumeration protocol developed in this study provides a simplified approach for indoor air quality assessment. Implementation of cold-plasma technology in healthcare settings could reduce respiratory infection risks for susceptible populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Effect of Carbon-Fiber Negative Air Ionization (NAI) on Air Sampled in a Pediatric Hospital: Culturable Airborne Bacteria, Species Diversity, and Biofilm Formation.Microorganisms · 2026
- Developing a sensitive indoor air surveillance approach for nosocomial pathogens and antimicrobial resistancebioRxiv · 2026
- Response of culturable bacteria and their resistance to air purification across compartments.Frontiers in public health · 2026
- Inactivation of airborne pathogen surrogates by triethylene glycolApplied and Environmental Microbiology · 2026
- Spatiotemporal Contamination Characteristics, Bacterial Community Structure, and Airflow-Mediated Transport of Bacterial Aerosols in a Pediatric Emergency Consulting Room.Environmental research · 2026
- Development and production of a handy cold plasma device for the treatment of skin indicationsCurrent Directions in Biomedical Engineering · 2026