Air disinfection effect of different disinfection methods in high-risk healthcare spaces.
Jiamin Wang, Mengge Han, Yixin Cui, Wei Sun, Yan Shen, Jiabing Lin, Xiang Chen, Wenbo Wan,
Department of Hospital Infection Management, Zhongshan Hospital, Fudan University, Shanghai, China. · Institute of Hospital Infection and Control, Fudan University, Shanghai, China.
Key points
From the paper's conclusion- These findings suggest that 222-nm UV upper-room air disinfection may reduce airborne bacterial concentrations and improve air hygiene quality under routine clinical conditions.
Abstract
To evaluate the field performance of human-occupied air disinfection strategies in high-risk healthcare areas, field tests were conducted in the high-risk triage area, infectious disease ward, and dental clinics of a top-tier academic medical center. Existing air disinfection or ventilation-based control measures, including plasma air disinfection devices, ultraviolet (UV) air cleaners, and negative-pressure ventilation systems, were evaluated alone or in combination with a 222-nm UV upper-room air disinfection system. No air disinfection intervention was used in the control group. Air sampling was performed hourly during daytime clinical hours using a six-stage impactor microbial sampling method or a settle plate method. Compared with no-disinfection controls or existing-measure comparators, airborne bacterial concentrations were generally lower in the 222-nm UV group or 222-nm UV add-on groups across multiple clinical settings. Percentage reductions relative to valid comparators ranged from 48.04% to 73.74% for 222-nm UV alone and from 6.86% to 73.77% for 222-nm UV used as an add-on to existing measures. These findings suggest that 222-nm UV upper-room air disinfection may reduce airborne bacterial concentrations and improve air hygiene quality under routine clinical conditions. Because the study was not designed to determine mechanistic synergy, observed reductions in combined-use groups are presented as add-on field performance rather than evidence of synergistic interaction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Germicidal Ultraviolet C (UV-C) Light for Surface Disinfection in Hospitals: Mapping the Evidence on Devices, Parameters, Effectiveness, and ImplementationHygiene · 2026
- Validated computational modeling to evaluate spatial inactivation of airborne pathogens by Far-UVC irradiation.Photochemistry and photobiology · 2026
- Defining Operational UV-C Dose Requirements for Autonomous Disinfection of Clinically Relevant Pathogens Across Healthcare and High-Touch SurfacesbioRxiv · 2026
- In-Situ Disinfection of Hospital Privacy Curtains Using a Next-Generation Aerosolized Hydrogen Peroxide SystemmedRxiv · 2026
- Large-scale chamber tests of in-room germicidal ultraviolet (GUV) systems: Review and best practicesBuilding and Environment · 2026
- Airborne and Surface Bacteria in ORs: Integration of ASHRAE-Compliant Ventilation and Active UV-C Air Treatment.AORN journal · 2026