Subject-Specific Finite Element Modelling of Le Fort I Osteotomy Fixation: Biomechanical Insights Comparing Patient-Specific Implants and Conventional Miniplates.
Olina Rios, Sarah Latreche, Yannick Tillier, Charles Savoldelli
Department of Oral and Maxillo-Facial Surgery, Head and Neck Institute, University Hospital Center of Nice, 31 avenue de Valombrose, 06100 Nice, France. · Department of Computational Mechanics Physics CEMEF, MINES ParisTech, PSL Research University, Centre de Mise en Forme des Matériaux (CEMEF), 06904 Sophia Antipolis, France.
Key points
From the paper's conclusion- Conclusions: These findings highlight the influence of surgical movement on fixation biomechanics and support the integration of biomechanical personalization alongside anatomical planning in orthognathic surgery.
Abstract
Background: Stable fixation is essential to prevent relapse after Le Fort I osteotomy, particularly during the early postoperative period when the fixation system bears the full masticatory load. Patient-specific implants (PSI) have been increasingly used, but their biomechanical behavior under postoperative surgical conditions remains insufficiently investigated. The aim of this study was to evaluate PSI fixation using subject-specific finite element modelling based on real surgical plans. Methods: Two patient-specific models were developed from cone-beam computed tomography (CBCT) data of patients undergoing bimaxillary orthognathic surgery. For each case, two fixation strategies were simulated: a multiarm patient-specific plate and conventional L-shaped miniplates. Von Mises stress distribution and relative displacement were analyzed for fixation devices and bone segments. Results: PSI fixation reduced stress levels in plates and screws while maintaining comparable global stability. However, its effect on bone stress differed between the two models. In Patient 2, whose surgical plan included greater maxillary advancement and posterior impaction, PSI fixation was associated with higher bone stress and a micrometric increase in displacement. Conclusions: These findings highlight the influence of surgical movement on fixation biomechanics and support the integration of biomechanical personalization alongside anatomical planning in orthognathic surgery.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis.Journal of functional biomaterials · 2026
- Patient-Specific Versus Conventional Manually Bent Osteosynthesis Plates in Orthognathic Surgery: A Systematic Review and Meta-Analysis of Three-Dimensional Accuracy, Long-Term Skeletal Stability, Operative Efficiency, and Postoperative ComplicationsSurgeries · 2026
- Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element AnalysisJournal of Clinical Medicine · 2026
- Patient-Specific Sensitivity of Osteotomy Interface Modelling in Mandibular Reconstruction.Oral oncology · 2026
- Finite element analysis of patient specific three-dimensional titanium plate versus conventional two miniplate fixation for mandibular angle fractures.BMC oral health · 2026