Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element Analysis
Sergio Adrian Olate, Víctor Ravelo, H. Garcia Guevara, Roberto Sacco, Marcelo Parra, Márcio de Moraes
Universidad de La Frontera · Hospital Clínico Universitario de Caracas
Key points
From the paper's conclusion- Objectives: The aim of this study was to evaluate the influence of plate design, plate thickness, and fixation architecture on the mechanical stability of mandibular advancement using finite element analysis.
Abstract
Background: Mandibular advancement is a commonly performed surgical procedure for the treatment of mandibular retrognathia and Class II dentofacial deformities; however, large advancements impose increased mechanical demands on fixation systems. Despite the availability of various fixation strategies, standard straight plate systems remain widely used worldwide due to their availability, cost-effectiveness, and clinical familiarity. Continuous biomechanical evaluation of these systems is therefore required to optimize stability and performance under demanding conditions. Objectives: The aim of this study was to evaluate the influence of plate design, plate thickness, and fixation architecture on the mechanical stability of mandibular advancement using finite element analysis. Methods: A three-dimensional finite element model simulating a unilateral mandibular osteotomy with a 10 mm gap was generated as mandibular advancement was developed. Fifteen fixation configurations were analyzed, including variations in plate design (simple and reinforced plates with partial or total inferior mesh extension), plate thickness (0.8 mm and 1.0 mm), and fixation architecture using independent plate systems (LN) or integrated fixation systems (FM). A vertical load was applied to the lower central incisor to simulate functional loading. Outcome measures included global equivalent stress considering screws and plate, equivalent stress within the plate, and global deformation of the fixation system. Results: The analyses demonstrated distinct mechanical behaviors among the evaluated configurations. Differences in stress distribution and deformation were observed according to plate design, thickness, and fixation architecture. Reinforced designs, increased plate thickness, and integrated fixation systems showed reduced deformation and more favorable stress distribution when compared with simple plate configurations. Conclusions: Plate design, thickness, and fixation architecture influenced the mechanical stability of mandibular advancement, supporting the importance of biomechanical optimization of standard fixation systems, particularly in large mandibular advancements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis.Journal of functional biomaterials · 2026
- Finite element analysis of patient specific three-dimensional titanium plate versus conventional two miniplate fixation for mandibular angle fractures.BMC oral health · 2026
- A Biomechanical Assessment of three Types of Plating Systems in a Combined Mandibular Parasymphysis and Angle Fracture - An In vitro Study.Annals of maxillofacial surgery · 2026
- Biomechanical Comparison of Monoplanar and Biplanar Miniplate Fixation for Unfavorable Mandibular Angle Fractures: A Finite Element Analysis.Cureus · 2026
- A novel plate design versus two conventional miniplates for treatment of mandibular angle fractures (a pilot randomized controlled clinical trial)BMC Oral Health · 2026
- In silico biomechanical evaluation of personalized A-shaped titanium plates for mandibular condylar base fractures.Computer methods in biomechanics and biomedical engineering · 2026