Finite element analysis of patient specific three-dimensional titanium plate versus conventional two miniplate fixation for mandibular angle fractures.
Asmaa M Abd Elfattah, Mostafa M Eldibany, Ragab S Hassan, Mona S Oraby
Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University, Alexandria, Egypt. asmaa.abdelfattah.dent@alexu.edu.eg. · Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
Key points
From the paper's conclusion- Patient specific and conventional fixation techniques exhibited distinct biomechanical characteristics under simulated loading conditions. Both implant design and fixation configuration influence the biomechanical behaviour of mandibular angle fracture fixation.
Abstract
BACKGROUND: Mandibular angle fractures are among the most common maxillofacial fractures and represent a biomechanically challenging region because of complex functional loading. Conventional two miniplate fixation is widely used to provide fracture stability; however, stress concentration within the fixation hardware may affect its biomechanical performance. Recent advances in computer-aided design and manufacturing (CAD/CAM) have enabled the development of patient specific fixation techniques designed to improve implant adaptation and optimize stress distribution. OBJECTIVE: This study aimed to compare the biomechanical behaviour of a patient specific three-dimensional (3D) titanium plate and conventional two miniplate fixation for mandibular angle fractures using finite element analysis (FEA). MATERIALS AND METHODS: A three-dimensional mandibular model was reconstructed from computed tomography data obtained from a 25-year-old fully dentate male patient. Cortical and cancellous bone structures were generated using Mimics and Geomagic Design X software. Two fixation models and fixation hardware were assembled using SolidWorks software: Model A consisted of conventional two miniplate fixation, while Model B consisted of a patient specific three- dimensional titanium plate contoured along the tension zone of the mandible. The models were imported into ANSYS software for finite element analysis under simulated unilateral clenching conditions. Von Mises stress, maximum principal stress, and total displacement were evaluated under identical loading and boundary conditions. RESULTS: The patient specific 3D plate model demonstrated lower maximum von Mises stress within the fixation plate (326.19 MPa) compared with the conventional two miniplate system (417.48 MPa). Maximum principal stress in cortical bone was higher in the patient specific plate model (121.03 MPa) compared with the conventional fixation model (87.759 MPa). Total displacement was greater in the patient specific plate model (157.32 μm) than in the conventional system (131.47 μm). However, displacement values in both models remained within reported ranges considered acceptable for fracture healing. CONCLUSION: Patient specific and conventional fixation techniques exhibited distinct biomechanical characteristics under simulated loading conditions. Both implant design and fixation configuration influence the biomechanical behaviour of mandibular angle fracture fixation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Comparison of Monoplanar and Biplanar Miniplate Fixation for Unfavorable Mandibular Angle Fractures: A Finite Element Analysis.Cureus · 2026
- Patient-specific three-dimensional titanium plate versus conventional two-miniplate fixation for mandibular angle fractures: a randomized clinical trial.BMC oral health · 2026
- Does the biplane three-dimensional miniplate design provide stable fixation for mandibular angle fractures? A clinical study and proposal for novel radiographic criteria.Dental research journal · 2026
- Influence of Plate Design, Thickness, and Fixation Architecture on Mandibular Advancement Stability: A Finite Element AnalysisJournal of Clinical Medicine · 2026
- A novel plate design versus two conventional miniplates for treatment of mandibular angle fractures (a pilot randomized controlled clinical trial)BMC Oral Health · 2026
- Biomechanical Evaluation of Patient-Specific Titanium Fixation Systems for Segmental Le Fort I Osteotomy: A Finite Element Analysis.Journal of functional biomaterials · 2026