Meta-Analysis of Brand-Mixed Versus Brand-Unmixed Primary Total Hip Arthroplasty.
Daniel Elias, Bryan J M van de Wall, Jörg Bucher, Björn-Christian Link, Pascal C Haefeli
Department of Orthopedic and Trauma Surgery, Lucerne Cantonal Hospital, 6004 Lucerne, Switzerland.
Key points
From the paper's conclusion- This systematic review and meta-analysis aimed to compare revision outcomes between brand-mixed and brand-unmixed primary THA.
Abstract
Background/Objectives: Mixing implant components from different manufacturers in primary total hip arthroplasty (THA) remains controversial because of concerns regarding implant compatibility and revision risk. This systematic review and meta-analysis aimed to compare revision outcomes between brand-mixed and brand-unmixed primary THA. Methods: A PRISMA-compliant systematic review of PubMed/MEDLINE and Embase identified studies comparing brand-mixed and brand-unmixed primary THA. Reported time-to-event estimates were pooled as hazard ratios (HRs), and revision-event counts as odds ratios (ORs), using random-effects models. Results: Six retrospective observational studies comprising 1,185,948 primary THAs were included. The time-to-event analysis did not identify a statistically significant difference in all-cause revision between brand-mixed and brand-unmixed THA (HR 1.03; 95% CI 0.97-1.08; I2 = 0%). The complementary crude revision-event analysis likewise did not identify a statistically significant difference (OR 1.01; 95% CI 0.83-1.24), although substantial heterogeneity was present (I2 = 93%). A post hoc exploratory sensitivity analysis excluding metal-on-metal and ceramic-on-metal bearings and brand-mixed stem-head constructs was based on two studies and yielded an OR of 0.97 (95% CI 0.79-1.20; I2 = 95%). Certainty of evidence was low for the time-to-event analysis and very low for the event-based analyses. Conclusions: Available observational evidence did not identify a statistically significant association between brand mixing and all-cause revision following primary THA. However, these findings do not establish equivalence, universal component compatibility, or the safety of specific brand-mixed combinations and should be interpreted in light of the observational study designs, residual confounding, and heterogeneity in implant constructs.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Association of polyethylene type with revision and dislocation risk following primary total hip arthroplasty: a population-based cohort study from the Danish Hip Arthroplasty Register.Acta orthopaedica · 2026
- Volumetric Wear of Highly Cross-Linked Polyethylene Sockets in Total Hip Arthroplasty Differs Among Brands: A Retrieval Study.Journal of functional biomaterials · 2026
- Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.Bioengineering (Basel, Switzerland) · 2026
- Revision outcomes after failed hip resurfacing arthroplasty vary by failure indication and component strategy: A systematic review.Journal of experimental orthopaedics · 2026
- Cemented total hip arthroplasty reduces early complications: a Japanese nationwide propensity-matched studyArchives of Orthopaedic and Trauma Surgery · 2026
- Patient, surgeon, and institutional variation in dual-mobility component use in primary total hip arthroplasty : a retrospective cohort study using data from the National Joint Registry Study.The bone & joint journal · 2026