Journal of clinical medicine

Meta-Analysis of Brand-Mixed Versus Brand-Unmixed Primary Total Hip Arthroplasty.

Daniel Elias, Bryan J M van de Wall, Jörg Bucher, Björn-Christian Link, Pascal C Haefeli

Department of Orthopedic and Trauma Surgery, Lucerne Cantonal Hospital, 6004 Lucerne, Switzerland.

Meta-analysis

Key points

From the paper's conclusion
  • This systematic review and meta-analysis aimed to compare revision outcomes between brand-mixed and brand-unmixed primary THA.

Abstract

Background/Objectives: Mixing implant components from different manufacturers in primary total hip arthroplasty (THA) remains controversial because of concerns regarding implant compatibility and revision risk. This systematic review and meta-analysis aimed to compare revision outcomes between brand-mixed and brand-unmixed primary THA. Methods: A PRISMA-compliant systematic review of PubMed/MEDLINE and Embase identified studies comparing brand-mixed and brand-unmixed primary THA. Reported time-to-event estimates were pooled as hazard ratios (HRs), and revision-event counts as odds ratios (ORs), using random-effects models. Results: Six retrospective observational studies comprising 1,185,948 primary THAs were included. The time-to-event analysis did not identify a statistically significant difference in all-cause revision between brand-mixed and brand-unmixed THA (HR 1.03; 95% CI 0.97-1.08; I2 = 0%). The complementary crude revision-event analysis likewise did not identify a statistically significant difference (OR 1.01; 95% CI 0.83-1.24), although substantial heterogeneity was present (I2 = 93%). A post hoc exploratory sensitivity analysis excluding metal-on-metal and ceramic-on-metal bearings and brand-mixed stem-head constructs was based on two studies and yielded an OR of 0.97 (95% CI 0.79-1.20; I2 = 95%). Certainty of evidence was low for the time-to-event analysis and very low for the event-based analyses. Conclusions: Available observational evidence did not identify a statistically significant association between brand mixing and all-cause revision following primary THA. However, these findings do not establish equivalence, universal component compatibility, or the safety of specific brand-mixed combinations and should be interpreted in light of the observational study designs, residual confounding, and heterogeneity in implant constructs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Meta-Analysis of Brand-Mixed Versus Brand-Unmixed Primary Total Hip Arthroplasty — Science Skim