Association of polyethylene type with revision and dislocation risk following primary total hip arthroplasty: a population-based cohort study from the Danish Hip Arthroplasty Register.
Marwan Chabaita, Afrim Iljazi, Michala Skovlund Sørensen, Frank Eriksson, Søren Overgaard, Michael Mørk Petersen
Department of Orthopedic Surgery, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark. marwanchabaita@gmail.com. · Department of Orthopedic Surgery, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
Key points
From the paper's conclusion- Among 36 mm implants, HXLPE was associated with lower risk of dislocation, all-cause revision, and revision due to infection and dislocation. Among 32 mm implants, HXLPE was associated with lower risk of dislocation and aseptic loosening revision. These findings may suggest potential advantages of HXLPE, though caution is warranted given the observational design.
Abstract
BACKGROUND AND PURPOSE: Highly cross-linked polyethylene (HXLPE) has been widely adopted to address wear in total hip arthroplasty (THA), yet population-based evidence remains limited. We aimed to evaluate the long-term risk of all-cause revision, dislocation, and cause-specific revision according to polyethylene type in primary THA. METHODS: We conducted a population-based cohort study using data from the Danish Hip Arthroplasty Register and the Danish National Patient Register, including 48,618 patients undergoing primary THA for osteoarthritis from 2000 to 2016. Patients were followed until revision, dislocation, death, year 10, or December 2021. We compared HXLPE with non-HXLPE for patients receiving implants with 28 mm, 32 mm, and 36 mm femoral heads. We estimated standardized risk differences using targeted maximum likelihood estimation comparing polyethylene type stratified by femoral head size and standardized to age, sex, fixation, and Charlson Comorbidity Index. RESULTS: Standardized risk differences showed favorable results for HXLPE regarding all-cause revision (-3.1%, 95% confidence interval [CI] -4.5 to -1.6), dislocation (-1.9%, CI -3.1 to -0.6), revision due to dislocation (-1.3%, CI -1.9 to -0.7), and revision due to infection (-0.9%, CI -1.3 to -0.4) for 36 mm heads, and for dislocation (-1.4%, CI -2.6 to -0.2) and revision due to aseptic loosening (-0.8%, CI -1.1 to -0.5) for 32 mm heads. There was no difference between HXLPE and non-HXPLE for any outcomes for the 28 mm group. CONCLUSION: Among 36 mm implants, HXLPE was associated with lower risk of dislocation, all-cause revision, and revision due to infection and dislocation. Among 32 mm implants, HXLPE was associated with lower risk of dislocation and aseptic loosening revision. These findings may suggest potential advantages of HXLPE, though caution is warranted given the observational design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Volumetric Wear of Highly Cross-Linked Polyethylene Sockets in Total Hip Arthroplasty Differs Among Brands: A Retrieval Study.Journal of functional biomaterials · 2026
- The impact of glenoid polyethylene type, humeral head size and composition on revision risk following primary anatomic total shoulder arthroplasty for osteoarthritis.Journal of shoulder and elbow surgery · 2026
- Comparative outcomes of delta-on-delta and delta-on-highly cross-linked polyethylene bearings in total hip arthroplasty: a nationwide cohort study.Archives of orthopaedic and trauma surgery · 2026
- Improved Wear Performance of Highly Cross-Linked Versus Conventional Polyethylene in Dual Mobility Cups.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
- Ten-year insert wear and the migration of uncemented tibial and femoral components with either conventional polyethylene or sequentially annealed highly crosslinked polyethylene: a blinded randomized controlled trial using radiostereometric analysis.The bone & joint journal · 2026
- The 10- Year Clinical and Radiographic Outcomes of a Vitamin E-Infused Highly Cross-Linked Polyethylene Cup in Total Hip Arthroplasty: A Multicenter Cohort Study.The Journal of arthroplasty · 2026