Bioengineering (Basel, Switzerland)

Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.

Yasaman Tavakoli, Fatemeh Kanaani Nejad, Kartik Varsani, Roshan Latifi, Mohammad Poursalehian, Jad Ismail, Robert A Sershon

Department of Medicine, Mazandaran University of Medical Sciences, Sari 48157-33971, Iran. · Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz 71348-14336, Iran.

Observational

Key points

From the paper's conclusion
  • Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear.

Abstract

Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear. This structured narrative review asks for which bearing materials and fixation interfaces positioning accuracy plausibly alters the degradation and fixation pathways that govern survival, and how strong the evidence is for each link. We propose a conceptual model linking positioning to the local mechanical environment, material-specific degradation, biological response, and survival, and grade each link's evidence by study design. Enabling technologies consistently reduce outliers. Position-dependent degradation is well documented for conventional polyethylene, ceramic-on-ceramic, and metal-on-metal bearings, mainly from simulator, retrieval, and cohort studies. Highly cross-linked polyethylene appears to attenuate the wear penalty of malposition, although rim fatigue and impingement remain position-sensitive and vitamin E stabilization has no proven additional clinical benefit. In cementless TKA, varus alignment is associated with greater early tibial migration, a validated surrogate for loosening. Clinical translation remains limited: trials and registries show no consistent reduction in all-cause revision after TKA or THA, with lower dislocation after THA and a more favorable UKA signal as exceptions. Precision may matter most for position-sensitive bearings and cementless interfaces.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival — Science Skim