Navigation-Assisted and Robotic Total Hip, Knee, and Unicompartmental Arthroplasty: Reconciling Positioning Accuracy with Biomaterial Performance and Long-Term Implant Survival.
Yasaman Tavakoli, Fatemeh Kanaani Nejad, Kartik Varsani, Roshan Latifi, Mohammad Poursalehian, Jad Ismail, Robert A Sershon
Department of Medicine, Mazandaran University of Medical Sciences, Sari 48157-33971, Iran. · Medical Imaging Research Center, Shiraz University of Medical Sciences, Shiraz 71348-14336, Iran.
Key points
From the paper's conclusion- Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear.
Abstract
Navigation-assisted and robotic systems improve component positioning in total hip (THA), total knee (TKA), and unicompartmental knee arthroplasty (UKA), but whether this improves biomaterial performance and implant survival is unclear. This structured narrative review asks for which bearing materials and fixation interfaces positioning accuracy plausibly alters the degradation and fixation pathways that govern survival, and how strong the evidence is for each link. We propose a conceptual model linking positioning to the local mechanical environment, material-specific degradation, biological response, and survival, and grade each link's evidence by study design. Enabling technologies consistently reduce outliers. Position-dependent degradation is well documented for conventional polyethylene, ceramic-on-ceramic, and metal-on-metal bearings, mainly from simulator, retrieval, and cohort studies. Highly cross-linked polyethylene appears to attenuate the wear penalty of malposition, although rim fatigue and impingement remain position-sensitive and vitamin E stabilization has no proven additional clinical benefit. In cementless TKA, varus alignment is associated with greater early tibial migration, a validated surrogate for loosening. Clinical translation remains limited: trials and registries show no consistent reduction in all-cause revision after TKA or THA, with lower dislocation after THA and a more favorable UKA signal as exceptions. Precision may matter most for position-sensitive bearings and cementless interfaces.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Native varus angle does not affect the primary fixation of cementless TKA using kinematic alignment - A population-based FE study.Journal of biomechanics · 2026
- The Mark Coventry Award: Five-Year Outcomes of a Randomized Controlled Trial on Cemented versus Uncemented Total Knee Arthroplasty: The KneeFix TrialThe Journal of Arthroplasty · 2026
- Robotic Arthroplasty in Context: Balancing Evidence and Innovation in Joint Replacement.The Journal of bone and joint surgery. American volume · 2026
- Robotic arthroplasty and the gap between technical precision and clinical benefit.Journal of robotic surgery · 2026
- Comparable clinical outcomes but different postoperative Dynamic Alignment of the Knee (DyAK) patterns between cruciate-retaining and posterior-stabilized inserts in functionally aligned robotic-assisted total knee arthroplasty.Journal of experimental orthopaedics · 2026
- A new cementless tibial baseplate in kinematically aligned total knee arthroplasty has low migration and stabilizes at 3 months: A cohort study using radiostereometric analysis.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026