CT-Based Assessment of Femoral Stem Anteversion After Intentional Intraoperative Rotational Adjustment of a Single-Wedge Tapered Stem in Total Hip Arthroplasty.
Soon-Phil Yoon, Byung Woo Cho, Minjae So, Tae Hyeong Kim, Woo-Suk Lee
Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06229, Republic of Korea.
Key points
From the paper's conclusion- This study aimed to evaluate whether femoral stem anteversion can be intentionally adjusted towards a target angle and to identify factors associated with failure to achieve the intended correction.
Abstract
Background/Objectives: Prosthetic anteversion (PA) is generally considered to be constrained by three-point fixation in the sagittal plane. However, previous studies have reported inconsistent changes from native femoral anteversion (NFA) to prosthetic anteversion (PA), ranging from no appreciable change to a mean increase of approximately 8°, suggesting that PA may not be determined by femoral anatomy alone. This study aimed to evaluate whether femoral stem anteversion can be intentionally adjusted towards a target angle and to identify factors associated with failure to achieve the intended correction. Methods: We retrospectively reviewed 142 hips in 133 patients who underwent total hip arthroplasty with a target PA of 30°. Hips were divided into increased-anteversion (Group 1) and decreased-anteversion (Group 2) groups according to the intended correction relative to NFA. Correlations between targeted and actual correction angles and factors associated with correction failure were analyzed separately for each group. Results: Of 142 hips, 126 were classified as Group 1 and 16 as Group 2. PA significantly increased from NFA in Group 1 (12.72 ± 9.24° vs. 25.17 ± 7.13°; p < 0.001) but not in Group 2 (39.13 ± 6.73° vs. 37.84 ± 7.88°; p = 0.513). A lower CCR and intended decrease in anteversion were associated with correction failure. In Group 1, targeted and actual correction angles were significantly correlated (r = 0.633, p < 0.001). Conclusions: Femoral stem anteversion can be intentionally increased using a single-wedge tapered stem, particularly in femora with a high CCR. However, the feasibility of intentionally decreasing anteversion requires further investigation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accurate Acetabular Component Positioning in Total Hip Arthroplasty Using Preoperative CT and Anatomical Landmarks.Journal of clinical medicine · 2026
- Preoperative factors associated with alignment change from planned metaphyseal- to diaphyseal-dominant fixation in calcar-guided short-stem total hip arthroplasty.International orthopaedics · 2026
- The Triple-Tapered Uncemented Femoral Stems in Slight Varus Demonstrated Excellent Early Survivorship and Clinical Results.The Journal of arthroplasty · 2026
- Robotic navigation strategies for PFNA fixation: impact on one-time guide pin success rate and anteversion angle accuracy - a retrospective cohort study.Journal of robotic surgery · 2026
- Early Nontraumatic Periprosthetic Femoral Fracture After Total Hip Arthroplasty: A Case Report.Case reports in orthopedics · 2026
- Correcting to Neutral in Severely Deformed Total Knee Arthroplasty Is Associated With Reduced Aseptic Loosening and Instability.The Journal of arthroplasty · 2026