Robotic navigation strategies for PFNA fixation: impact on one-time guide pin success rate and anteversion angle accuracy - a retrospective cohort study.
Yong-Yi Huang, Gui-Xiang Tang, Yi-Fan Chen, Hong-Lan Li, Bin Huang, Wei-Ming Chen, Lin-Xia He
Department of Orthopaedics & Traumatology, Yunfu People's Hospital, Regional Cooperative Hospital of Nanfang Hospital, Southern Medical University, No. 120 Huanshi East Road, Yunfu, 527300, Guangdong Province, PR China. hyy065@163.com. · Department of Orthopaedics & Traumatology, Yunfu People's Hospital, Regional Cooperative Hospital of Nanfang Hospital, Southern Medical University, No. 120 Huanshi East Road, Yunfu, 527300, Guangdong Province, PR China.
Key points
From the paper's conclusion- We categorized patients into three groups by navigation strategy: G1 (double navigation, n = 41), G2 (single navigation, n = 40), and G3 (non-navigation, n = 40).
Abstract
This study evaluated the clinical efficacy of three navigation strategies (full robotic navigation, robotic navigation for the main nail only with freehand anteversion, and conventional freehand technique) in PFNA fixation for intertrochanteric fractures, analyzed factors affecting anteversion angle accuracy, and quantified the learning curve of robot-assisted surgery. A retrospective review was conducted on 121 intertrochanteric fracture cases managed with PFNA. We categorized patients into three groups by navigation strategy: G1 (double navigation, n = 41), G2 (single navigation, n = 40), and G3 (non-navigation, n = 40). Perioperative parameters (fluoroscopy time span, total fluoroscopy times, number of attempts, visible intraoperative blood loss, etc.) were compared among groups. The main metric assessed was the attempt frequency for anteversion determination (reflecting one-time success rate). Within G1, Spearman correlation and multivariable linear regression explored the associations between anteversion error and medullary canal diameter, as well as fluoroscopy times for main nail insertion. Curve estimation was used to evaluate learning curves for fluoroscopy time span and main nail insertion time. Baseline characteristics were similar across the three groups, with no significant differences (P > 0.05). The number of attempts to determine anteversion in G1 (1.22 ± 0.48) was significantly lower than in G2 (4.30 ± 2.49) and G3 (3.98 ± 1.93) (both P < 0.001). Regarding overall surgical efficiency, fluoroscopy time span in G1 (65.95 ± 8.71 min) was 12.0 min shorter (15.4% reduction, P < 0.05) than in G3 (77.93 ± 29.98 min), total fluoroscopy times (40.63 ± 7.89) were 16.3 fewer (28.6% reduction, P < 0.001); visible intraoperative blood loss (99.8 ± 91.2 mL) was 119.5 mL less (54.5% reduction, P < 0.001), and blood transfusion volume (0.73 ± 1.45 units) was significantly lower than in G3 (2.14 ± 1.72 units, P = 0.002). Compared with G2, G1 also showed significantly reduced fluoroscopy time span, total fluoroscopy times, and visible intraoperative blood loss (all P < 0.05). Main nail insertion time in G2 (43.78 ± 6.94 min) was significantly longer than in G3 (34.65 ± 17.59 min, P = 0.002), whereas G1 (37.80 ± 6.43 min) was not significantly different from G3. Within G1, anteversion error showed a strong negative correlation with medullary canal diameter (r = - 0.807, P < 0.001). Multiple regression identified medullary canal diameter as the only independent predictor of anteversion error (β = - 0.781, P < 0.001). Learning curve analysis demonstrated a marked reduction in fluoroscopy time span with robotic case order (R² = 0.644, P < 0.001), with the quadratic model providing the best fit. Full robotic navigation (double navigation) significantly improves anteversion-angle positioning efficiency (fewer attempts), reduces fluoroscopy time span and exposure frequency (suggesting lower radiation exposure), and decreases visible intraoperative blood loss. However, anteversion accuracy still depends on patient anatomy, particularly medullary canal diameter, necessitating consideration during preoperative planning. Moreover, the learning curve showed rapid early improvement, followed by a gradual plateau.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical outcomes and learning curve of robot-assisted percutaneous cannulated screw fixation for femoral neck fractures.Frontiers in surgery · 2026
- Robotic navigation-assisted versus conventional freehand placement of the infra-acetabular screw in acetabular fracture surgery: A retrospective comparative study.Injury · 2026
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026
- Improving Radiological Quality of Proximal Femoral Nail Antirotation Fixation for Intertrochanteric Femoral Fractures: A Closed-Loop Clinical Audit of Reduction Quality, Tip-Apex Distance, and Helical Blade Position.Cureus · 2026
- Robot-assisted navigation combined with a double reverse traction reduction frame for retrograde intramedullary nailing of extra-articular distal femoral fractures: a retrospective comparative cohort study.Frontiers in medicine · 2026
- A retrospective cohort study comparing combined TiRobot navigation and percutaneous minimally invasive FNS fixation versus conventional open reduction FNS for femoral neck fractures.Journal of robotic surgery · 2026