Preoperative factors associated with alignment change from planned metaphyseal- to diaphyseal-dominant fixation in calcar-guided short-stem total hip arthroplasty.
Kazuhiko Sonoda, Yusuke Kubo, Toshihiko Hara
Department of Orthopaedic Surgery, Iizuka Hospital, Iizuka, Japan. skazuhik@gmail.com. · Department of Orthopaedic Surgery, Iizuka Hospital, Iizuka, Japan.
Key points
From the paper's conclusion- A low planned stem position, often observed in hips with a relatively short femoral neck, and a larger neck-shaft angle increase the likelihood of deviation toward diaphyseal-dominant fixation. When these features are present, surgeons should consider planning with diaphyseal-dominant fixation or selecting an alternative stem design.
Abstract
PURPOSE: Calcar-guided short stems allow a certain degree of alignment variability and may result in different fixation patterns within the proximal femur. Consequently, postoperative fixation pattern does not always correspond to preoperative planning and may influence offset or leg-length reconstruction. This study aimed to identify preoperative factors associated with deviation from planned metaphyseal-dominant fixation in total hip arthroplasty (THA). METHODS: Sixty-two consecutive primary THAs using a calcar-guided short stem were analyzed. All hips were preoperatively planned using CT-based three-dimensional templating to achieve metaphyseal-dominant fixation. Preoperative variables included patient demographics, Dorr classification, neck-shaft angle, and a planned stem depth parameter defined as the height difference between the femoral saddle and the planned stem shoulder (planned stem height). Postoperative fixation pattern was classified as metaphyseal-dominant or diaphyseal-dominant, and factors associated with postoperative diaphyseal-dominant fixation were analyzed. RESULTS: Metaphyseal-dominant fixation was observed in 43 hips, whereas 19 hips demonstrated diaphyseal-dominant fixation. Multivariable analysis showed that a lower planned stem height and a larger neck-shaft angle were independently associated with postoperative diaphyseal-dominant fixation. The cutoff values were - 4.4 mm for planned stem height and 134.5° for neck-shaft angle. CONCLUSION: A low planned stem position, often observed in hips with a relatively short femoral neck, and a larger neck-shaft angle increase the likelihood of deviation toward diaphyseal-dominant fixation. When these features are present, surgeons should consider planning with diaphyseal-dominant fixation or selecting an alternative stem design.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Fracture Morphology and Extraction-Related Femoral Damages in Short Versus Standard Cementless Stems: Analyses of Vancouver B2 Fractures and Well-Fixed Nonfracture Revisions.Arthroplasty today · 2026
- Finite element analysis of different subtrochanteric osteotomy techniques in total hip arthroplasty for high hip dislocation.Bone & joint research · 2026
- Cementless calcar-guided short stems: 24-month clinical outcomes and migration analysis.Scientific reports · 2026
- The Triple-Tapered Uncemented Femoral Stems in Slight Varus Demonstrated Excellent Early Survivorship and Clinical Results.The Journal of arthroplasty · 2026
- CT-Based Assessment of Femoral Stem Anteversion After Intentional Intraoperative Rotational Adjustment of a Single-Wedge Tapered Stem in Total Hip Arthroplasty.Journal of clinical medicine · 2026
- EP4.6 Femoral Neck Morphology: A CT-Based Anatomic Framework Informs Medial Collar Design for Contemporary Collared Cementless Femoral StemsJournal of Hip Preservation Surgery · 2026