Correcting to Neutral in Severely Deformed Total Knee Arthroplasty Is Associated With Reduced Aseptic Loosening and Instability.
Wayne Hoskins, Charles A Gusho, Kenrick Rosser, Matthew Lim, Kate Dunstall, Kelly G Vince
Northland Orthopaedic Research Consortium, Whangārei Hospital, Te Whatu Ora Te Tai Tokerau, Whangārei, New Zealand; Northland Knee & Hip, Whangārei, New Zealand; Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Parkville, Victoria, Australia. Electronic address: wayne.hoskins@outlook.com. · Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, United States.
Key points
From the paper's conclusion- In severely deformed TKA, particularly extreme valgus, correcting the mechanical axis toward neutral was associated with lower aseptic revision under two alignment frameworks. Preserving the phenotype, or adding stems or constraints, was not.
Abstract
BACKGROUND: Severe coronal deformity in total knee arthroplasty (TKA) forces a choice between preserving constitutional alignment, correcting toward neutral, and adding stems or constraint. We tested which decision was associated with aseptic revision. METHODS: We studied 1,566 primary TKAs in 1,286 patients who had paired long-leg radiographs and a minimum 2-year follow-up, stratified by preoperative Kennedy zone (KZ) into varus (KZ 0 and 1) and valgus (KZ 3 to 5). The nine decisions tested were mechanical hip-knee-ankle (mHKA) angle correction, KZ correction, Coronal Plane Alignment of the Knee (CPAK) phenotype V or II, CPAK preservation, tibial or femoral stem, and posterior-stabilized or constrained bearing. Adjusted Fine-Gray subdistribution hazard ratios (sHRs), with death as a competing event, were clustered by patient. RESULTS: Limb-axis correction was associated with lower aseptic revision in both strata, whether defined by an mHKA angle of 177 to 183° (varus sHR 0.43, P = 0.043; valgus sHR 0.25, P = 0.004) or by a central KZ (sHR 0.23, P < 0.001; sHR 0.31, P = 0.012), and was largest in extreme valgus (KZ 5; sHR 0.17, P = 0.026). The 5-year incidence of revision for loosening or instability was 0.98 versus 3.26% in corrected and uncorrected knees (sHR 0.22, P = 0.001). Phenotype targets, stems, and constraints were not statistically significant. CONCLUSIONS: In severely deformed TKA, particularly extreme valgus, correcting the mechanical axis toward neutral was associated with lower aseptic revision under two alignment frameworks. Preserving the phenotype, or adding stems or constraints, was not.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Can All Knees Be Restored? Reproduction of Pre-Arthritic Coronal Alignment and Aseptic Revision Risk by Preoperative Phenotype: An Exploratory Stratified Competing-Risks Analysis With a Targeted Bayesian Sub-Analysis.The Journal of arthroplasty · 2026
- Constitutional Restoration versus Mechanical Neutral in the Younger Total Knee Arthroplasty: A Pre-Specified Bayesian Competing-Risk Analysis of Alignment Accuracy and Aseptic Revision.The Journal of arthroplasty · 2026
- Fibula-Tibia Distance and Revision for Instability After Primary Total Knee Arthroplasty: An Exploratory Case-Control Study Addressing Rotational Confounding.Journal of clinical medicine · 2026
- Do Not Chase Symmetric Gaps: Native Asymmetry Linked to Better Recovery in Fixed-Deformity Total Knee Arthroplasty.The Journal of arthroplasty · 2026
- Combined Coronal and Rotational Malalignment Is an Independent Predictor of Survivorship After Total Knee Arthroplasty: Results at a Mean Follow-up of 20.5 Years.The Journal of arthroplasty · 2026
- Influence of total knee arthroplasty on coronal plane phenotypes and associated clinical outcomes: a CPAK-based comparison between mechanical and functional alignment.Journal of robotic surgery · 2026