The Journal of arthroplasty

Correcting to Neutral in Severely Deformed Total Knee Arthroplasty Is Associated With Reduced Aseptic Loosening and Instability.

Wayne Hoskins, Charles A Gusho, Kenrick Rosser, Matthew Lim, Kate Dunstall, Kelly G Vince

Northland Orthopaedic Research Consortium, Whangārei Hospital, Te Whatu Ora Te Tai Tokerau, Whangārei, New Zealand; Northland Knee & Hip, Whangārei, New Zealand; Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Parkville, Victoria, Australia. Electronic address: wayne.hoskins@outlook.com. · Missouri Orthopaedic Institute, University of Missouri, Columbia, Missouri, United States.

Key points

From the paper's conclusion
  • In severely deformed TKA, particularly extreme valgus, correcting the mechanical axis toward neutral was associated with lower aseptic revision under two alignment frameworks. Preserving the phenotype, or adding stems or constraints, was not.

Abstract

BACKGROUND: Severe coronal deformity in total knee arthroplasty (TKA) forces a choice between preserving constitutional alignment, correcting toward neutral, and adding stems or constraint. We tested which decision was associated with aseptic revision. METHODS: We studied 1,566 primary TKAs in 1,286 patients who had paired long-leg radiographs and a minimum 2-year follow-up, stratified by preoperative Kennedy zone (KZ) into varus (KZ 0 and 1) and valgus (KZ 3 to 5). The nine decisions tested were mechanical hip-knee-ankle (mHKA) angle correction, KZ correction, Coronal Plane Alignment of the Knee (CPAK) phenotype V or II, CPAK preservation, tibial or femoral stem, and posterior-stabilized or constrained bearing. Adjusted Fine-Gray subdistribution hazard ratios (sHRs), with death as a competing event, were clustered by patient. RESULTS: Limb-axis correction was associated with lower aseptic revision in both strata, whether defined by an mHKA angle of 177 to 183° (varus sHR 0.43, P = 0.043; valgus sHR 0.25, P = 0.004) or by a central KZ (sHR 0.23, P < 0.001; sHR 0.31, P = 0.012), and was largest in extreme valgus (KZ 5; sHR 0.17, P = 0.026). The 5-year incidence of revision for loosening or instability was 0.98 versus 3.26% in corrected and uncorrected knees (sHR 0.22, P = 0.001). Phenotype targets, stems, and constraints were not statistically significant. CONCLUSIONS: In severely deformed TKA, particularly extreme valgus, correcting the mechanical axis toward neutral was associated with lower aseptic revision under two alignment frameworks. Preserving the phenotype, or adding stems or constraints, was not.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Correcting to Neutral in Severely Deformed Total Knee Arthroplasty Is Associated With Reduced Aseptic Loosening and Instability — Science Skim