Implementation of Intraoperative Cone-Beam CT (Loop-X) in an Established Robotic-Assisted Pedicle Screw Program: An Epoch-Based Cohort Study
Julien N. Jost, Kristina Catalano, Jaqueline Lattmann, Debora Cipriani, Thomas Rhomberg, Lukas Andereggen, Gerrit A. Schubert, Markus Bruder
Kantonsspital Aarau · University of Bern
Key points
From the paper's conclusion- These findings support feasibility in practice, but do not establish superiority, equivalence, or imaging-specific effects.
Abstract
Background/Objectives: Reliable intraoperative imaging is essential for robotic-assisted (RA) pedicle screw placement. Mobile intraoperative cone-beam CT (iCBCT) systems like Loop-X have been introduced into RA workflows, but implementation data remain limited. We evaluated whether Loop-X introduction was associated with efficiency or safety, and whether associations differed by surgeon experience. Methods: We performed a retrospective epoch-based cohort study of 146 patients undergoing RA pedicle screw placement using 3D C-arm navigation (3D-BV) or Loop-X iCBCT. Outcomes were operating room (OR) time, estimated blood loss (EBL), and length of stay (LOS). The safety endpoint was 30-day complications (Clavien–Dindo grade III or higher). Multivariable regression models adjusted for patient- and procedure-related covariates; the complication model was kept parsimonious because of the limited number of events. Interaction terms tested surgeon experience. Results: After adjustment, implementation phase was not independently associated with OR time (β 30.76 min, 95% CI −31.97 to 93.48; p = 0.33), EBL (β −19.94 mL, 95% CI −287.01 to 247.14; p = 0.88), or LOS (β 3.21 days, 95% CI −3.31 to 9.72; p = 0.33). No significant interaction with surgeon experience was detected. Major complications occurred in 16 of 146 cases (11.0%) and were not associated with Loop-X implementation (OR 0.41, 95% CI 0.10–1.74; p = 0.224). Patient factors and procedural complexity were the main determinants of outcomes. Conclusions: In this cohort, Loop-X implementation in an RA pedicle screw program was not associated with deterioration in perioperative efficiency or short-term safety after adjustment. These findings support feasibility in practice, but do not establish superiority, equivalence, or imaging-specific effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026
- O-arm Navigation-assisted Extreme Lateral Interbody Fusion Utilizing SureTrak Device.Neurologia medico-chirurgica · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Robot-assisted versus pedicle projection localization in unilateral biportal endoscopic spine surgery: a trade-off analysis of fluoroscopy use, procedural time, and learning curve.Journal of robotic surgery · 2026
- SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patientNeuro-Oncology · 2026
- Robotic navigation-assisted versus conventional freehand placement of the infra-acetabular screw in acetabular fracture surgery: A retrospective comparative study.Injury · 2026