SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patient
Carlin Chuck, Alice Lin, Elaina Wang, Sumaiya Sayeed, Tori Riccelli, Natalie Amaral-Nieves, Santos Santos Fontanez, Esha Karayi,
Key points
From the paper's conclusion- Our experience suggests that mobile cone‑beam CT achieves stereotactic accuracy, workflow efficiency, and safety outcomes equivalent to those obtained with fixed-gantry diagnostic‑quality intraoperative CT, while meaningfully lowering radiation exposure.
Abstract
Robotic neurosurgery depends on precise spatial registration. We evaluated the accuracy and efficiency of mobile cone‑beam CT relative to a fixed-gantry intraoperative CT platform in guiding robotic‑assisted intracranial stereotactic procedures. Clinical data from 66 consecutive patients who underwent robot‑assisted stereotactic procedures for neuro‑oncologic indications between 2023 and 2026 were prospectively collected. Statistical comparisons were performed using t-tests, Mann-Whitney U tests, or multivariate analysis. Fixed-gantry intraoperative CT (Airo) was used for the initial 30 patients (35 trajectories), after which the subsequent 36 patients (39 trajectories) underwent procedures guided by mobile cone‑beam CT (Ziehm). The patient and lesion characteristics were comparable across the cohorts. In a multivariate analysis adjusting for procedure type and trajectory number, we found no significant differences in stereotaxy setup time between the two imaging platforms (defined as the time required for patient positioning, imaging, registration, and landmark verification; mean [SD] Ziehm: 62.2 [22.6] versus Airo: 58.8 [12.7] minutes, p = 0.447). The stereotactic accuracy achieved was also comparable between the two imaging platforms: radial error at the entry point (Ziehm: 0.83 [0.62]mm versus Airo: 0.68 [0.58]mm, p = 0.286) and at the target (Ziehm: 0.96 [0.57]mm versus Airo: 0.88 [0.70]mm, p = 0.438). Finally, there were no significant differences in procedural complications (one biopsy site hematoma in the Airo arm), length of hospital stay (median [IQR] hospital stay of 1 [1,2] day for Ziehm and 1 [1,2] for Airo, p = 0.408), and 30-day readmission between the two cohorts (two medical admissions unrelated to the biopsy in the Airo cohort). Our experience suggests that mobile cone‑beam CT achieves stereotactic accuracy, workflow efficiency, and safety outcomes equivalent to those obtained with fixed-gantry diagnostic‑quality intraoperative CT, while meaningfully lowering radiation exposure.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Robot-assisted versus conventional cranial stereotactic neurosurgery: a systematic review and meta-analysis of targeting accuracy, procedural efficiency, and safety.Journal of robotic surgery · 2026
- Robots for CT-guided needle insertion: clinical implementation and future perspectives.Japanese journal of radiology · 2026
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026
- Cone-beam computed tomography augmented-fluoroscopy-guided center-strike targeting during peripheral bronchoscopy: robotic vs. manual catheters.Journal of thoracic disease · 2026
- Robotic Needle Insertion for CT-guided Percutaneous Biopsy of Thoracoabdominal Lesions: A Prospective Multicenter Randomized Trial.Radiology. Imaging cancer · 2026
- Robot-assisted CT-guided interventions: Where are we now and where are we going?European radiology · 2026