Neuro-Oncology

SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patient

Carlin Chuck, Alice Lin, Elaina Wang, Sumaiya Sayeed, Tori Riccelli, Natalie Amaral-Nieves, Santos Santos Fontanez, Esha Karayi,

Observational · n=66

Key points

From the paper's conclusion
  • Our experience suggests that mobile cone‑beam CT achieves stereotactic accuracy, workflow efficiency, and safety outcomes equivalent to those obtained with fixed-gantry diagnostic‑quality intraoperative CT, while meaningfully lowering radiation exposure.

Abstract

Robotic neurosurgery depends on precise spatial registration. We evaluated the accuracy and efficiency of mobile cone‑beam CT relative to a fixed-gantry intraoperative CT platform in guiding robotic‑assisted intracranial stereotactic procedures. Clinical data from 66 consecutive patients who underwent robot‑assisted stereotactic procedures for neuro‑oncologic indications between 2023 and 2026 were prospectively collected. Statistical comparisons were performed using t-tests, Mann-Whitney U tests, or multivariate analysis. Fixed-gantry intraoperative CT (Airo) was used for the initial 30 patients (35 trajectories), after which the subsequent 36 patients (39 trajectories) underwent procedures guided by mobile cone‑beam CT (Ziehm). The patient and lesion characteristics were comparable across the cohorts. In a multivariate analysis adjusting for procedure type and trajectory number, we found no significant differences in stereotaxy setup time between the two imaging platforms (defined as the time required for patient positioning, imaging, registration, and landmark verification; mean [SD] Ziehm: 62.2 [22.6] versus Airo: 58.8 [12.7] minutes, p = 0.447). The stereotactic accuracy achieved was also comparable between the two imaging platforms: radial error at the entry point (Ziehm: 0.83 [0.62]mm versus Airo: 0.68 [0.58]mm, p = 0.286) and at the target (Ziehm: 0.96 [0.57]mm versus Airo: 0.88 [0.70]mm, p = 0.438). Finally, there were no significant differences in procedural complications (one biopsy site hematoma in the Airo arm), length of hospital stay (median [IQR] hospital stay of 1 [1,2] day for Ziehm and 1 [1,2] for Airo, p = 0.408), and 30-day readmission between the two cohorts (two medical admissions unrelated to the biopsy in the Airo cohort). Our experience suggests that mobile cone‑beam CT achieves stereotactic accuracy, workflow efficiency, and safety outcomes equivalent to those obtained with fixed-gantry diagnostic‑quality intraoperative CT, while meaningfully lowering radiation exposure.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

SURG-27 Fixed gantry versus mobile cone‑beam CT in guiding Robot‑assisted stereotaxis: a neuro-oncologic experience of 66 patient — Science Skim