Robotic navigation-assisted versus conventional freehand placement of the infra-acetabular screw in acetabular fracture surgery: A retrospective comparative study.
Wenhao Cao, Zhongxuan Chen, Haoyu Liu, Nazhi Zhan, Jie He, Lin Qi, Jiaqi Li, Yubo Zheng,
Department of Orthopaedic Surgery, Fourth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Beijing, China. · Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA.
Key points
From the paper's conclusion- Robotic navigation-assisted IAS placement was associated with significantly higher screw-placement accuracy and greater procedural efficiency than the conventional freehand technique, without compromising fracture reduction quality, hip function, or safety.
Abstract
BACKGROUND: The infra-acetabular screw (IAS) is an important component of fixation constructs for complex acetabular fractures, but accurate freehand placement is technically demanding, and evidence on robotic navigation-assisted IAS placement remains limited. This study compared robotic navigation-assisted (RA) and conventional fluoroscopic freehand (CF) IAS placement in acetabular fracture surgery. METHODS: In this retrospective study, 53 patients with acetabular fractures who underwent IAS fixation between June 2022 and July 2024 were included, 28 underwent RA placement using the HoloSight robotic navigation system and 25 underwent CF placement. The primary outcome was screw-placement accuracy, graded on postoperative CT according to the Lonstein criteria. Secondary outcomes included the number of guide-wire adjustments, fluoroscopy frequency, IAS insertion time, total operative time, intraoperative blood loss, fracture reduction quality, hip function, and complications. RESULTS: The grade 0 (no cortical penetration) rate was higher in the RA group than in the CF group (96.4% [27/28] vs. 60.0% [15/25], p = 0.005). RA placement was associated with fewer guide-wire adjustments (0.07 ± 0.26 vs. 3.60 ± 1.15), fewer fluoroscopies (9.32 ± 1.66 vs. 21.28 ± 3.18), shorter IAS insertion time (10.36 ± 2.50 vs. 26.68 ± 4.11 min), shorter total operative time (134.54 ± 15.46 vs. 155.80 ± 18.48 min), and less intraoperative blood loss (468.21 ± 84.68 vs. 588.40 ± 80.76 mL) (all p < 0.001). The mean follow-up duration was 15.7 ± 2.0 months (range, 13-22 months). Reduction quality, hip function, and complication rates did not differ significantly between the two groups. CONCLUSIONS: Robotic navigation-assisted IAS placement was associated with significantly higher screw-placement accuracy and greater procedural efficiency than the conventional freehand technique, without compromising fracture reduction quality, hip function, or safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Retrograde posterior column acetabular screw: robotically assisted and CT-guided minimally invasive procedureDie Unfallchirurgie · 2026
- Robotic navigation strategies for PFNA fixation: impact on one-time guide pin success rate and anteversion angle accuracy - a retrospective cohort study.Journal of robotic surgery · 2026
- Robot-assisted versus freehand cannulated-screw fixation for femoral neck fractures: a systematic review of technical, clinical and adoption outcomes.Journal of robotic surgery · 2026
- [Study on Holosight robot-assisted fixation versus fixation via sinus tarsi approach in treatment of calcaneal fractures].PubMed · 2026
- Clinical application of robot-assisted fixation for calcaneal fractures: a meta-analysis with subgroup comparisons.Journal of robotic surgery · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026