Robotic navigation-assisted versus conventional freehand placement of the infra-acetabular screw in acetabular fracture surgery: A retrospective comparative study.

Wenhao Cao, Zhongxuan Chen, Haoyu Liu, Nazhi Zhan, Jie He, Lin Qi, Jiaqi Li, Yubo Zheng,

Department of Orthopaedic Surgery, Fourth Medical Center of Chinese PLA General Hospital, No. 51 Fucheng Road, Beijing, China. · Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, USA.

Observational · n=53

Key points

From the paper's conclusion
  • Robotic navigation-assisted IAS placement was associated with significantly higher screw-placement accuracy and greater procedural efficiency than the conventional freehand technique, without compromising fracture reduction quality, hip function, or safety.

Abstract

BACKGROUND: The infra-acetabular screw (IAS) is an important component of fixation constructs for complex acetabular fractures, but accurate freehand placement is technically demanding, and evidence on robotic navigation-assisted IAS placement remains limited. This study compared robotic navigation-assisted (RA) and conventional fluoroscopic freehand (CF) IAS placement in acetabular fracture surgery. METHODS: In this retrospective study, 53 patients with acetabular fractures who underwent IAS fixation between June 2022 and July 2024 were included, 28 underwent RA placement using the HoloSight robotic navigation system and 25 underwent CF placement. The primary outcome was screw-placement accuracy, graded on postoperative CT according to the Lonstein criteria. Secondary outcomes included the number of guide-wire adjustments, fluoroscopy frequency, IAS insertion time, total operative time, intraoperative blood loss, fracture reduction quality, hip function, and complications. RESULTS: The grade 0 (no cortical penetration) rate was higher in the RA group than in the CF group (96.4% [27/28] vs. 60.0% [15/25], p = 0.005). RA placement was associated with fewer guide-wire adjustments (0.07 ± 0.26 vs. 3.60 ± 1.15), fewer fluoroscopies (9.32 ± 1.66 vs. 21.28 ± 3.18), shorter IAS insertion time (10.36 ± 2.50 vs. 26.68 ± 4.11 min), shorter total operative time (134.54 ± 15.46 vs. 155.80 ± 18.48 min), and less intraoperative blood loss (468.21 ± 84.68 vs. 588.40 ± 80.76 mL) (all p < 0.001). The mean follow-up duration was 15.7 ± 2.0 months (range, 13-22 months). Reduction quality, hip function, and complication rates did not differ significantly between the two groups. CONCLUSIONS: Robotic navigation-assisted IAS placement was associated with significantly higher screw-placement accuracy and greater procedural efficiency than the conventional freehand technique, without compromising fracture reduction quality, hip function, or safety.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers