Dosimetric Characterization Using Quantitative Magnetic Resonance Imaging of PAGAT and Gd-PAGAT Polymer Gel Dosimeters at High Gd Concentration.
Melani Fuentealba, Gerardo Belmar, Mauricio Santibáñez
Departamento de Cs. Físicas, Universidad de La Frontera, Temuco 4811230, Chile. · Departamento de Tecnología Médica, Universidad de Concepción, Concepción 4070386, Chile.
Key points
From the paper's conclusion- These findings demonstrate that R2 mapping overcomes the limitations imposed by extreme T1 shortening, extending the applicability of Gd-PAGAT dosimeters for three-dimensional dose enhancement studies in low-energy radiotherapy.
Abstract
Gadolinium-doped polymer gel dosimeters enable experimental evaluation of dose enhancement in low-energy radiotherapy, although the high Gd concentrations required substantially alter their magnetic relaxation properties, making the optimal Magnetic Resonance Imaging (MRI) readout uncertain. This study characterized the dosimetric response of PAGAT and Gd-PAGAT (9 mg/mL Gd) irradiated with a 150 kVp X-ray beam from 1 to 10 Gy using quantitative 1.5 T MRI. Quantitative R1 and R2 maps were obtained from variable flip-angle spoiled gradient echo (SPGR) and multi-echo spin echo (MSE) sequences, respectively, and validated by UV-Vis spectrophotometry. R1 showed no significant dose dependence in Gd-PAGAT because of severe T1 shortening. In contrast, R2 exhibited a robust response, with second-order polynomial fits (R2 = 0.9984 for PAGAT and 0.9969 for Gd-PAGAT) and linear behavior between 1 and 7 Gy. The dose sensitivity of Gd-PAGAT was 2.84 ± 0.19 times higher than that of PAGAT (0.5328 vs. 0.1949 s-1·Gy-1). Spectrophotometry confirmed the PAGAT calibration but showed markedly lower sensitivity for Gd-PAGAT, particularly at low doses. These findings demonstrate that R2 mapping overcomes the limitations imposed by extreme T1 shortening, extending the applicability of Gd-PAGAT dosimeters for three-dimensional dose enhancement studies in low-energy radiotherapy.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of an acrylic acid hydrogel dosimeter for 3-D dose verification in radiotherapy using MRIPLoS ONE · 2026
- Predicting Signal Intensity Profiles for Various MRI Contrast Agent Injection Strategies: Including Measurement of Relaxivities in Oxygenated Whole Human Blood for Gadopiclenol, Gadoterate Meglumine and Gadoteridol.Journal of magnetic resonance imaging : JMRI · 2026
- Development of a 3D Slicer Extension for MR-Based Gel Dosimetry AnalysisJournal of Physics: Conference Series · 2026
- MRI Guided Radiotherapy using Deformable Gel DosimetryJournal of Physics: Conference Series · 2026
- Irradiation-induced modulation of T2 relaxation times in sucrose solutions: a novel externally controlled design strategy for quantitative magnetic resonance imaging phantoms.Radiological physics and technology · 2026
- Preliminary investigation of iodine-doped MR-based polymer gel dosimeter for fiducial-free tumour-tracking radiotherapy.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2026