Journal of magnetic resonance imaging : JMRI

Predicting Signal Intensity Profiles for Various MRI Contrast Agent Injection Strategies: Including Measurement of Relaxivities in Oxygenated Whole Human Blood for Gadopiclenol, Gadoterate Meglumine and Gadoteridol.

Jeffrey H Maki, Alex J Barker, Toshimasa J Clark, Gregory J Wilson

Department of Radiology, University of Colorado Anschutz, Aurora, Colorado, USA. · Department of Radiology, Section of Pediatric Radiology, University of Colorado Anschutz, Children's Hospital Colorado, Aurora, Colorado, USA.

Key points

From the paper's conclusion
  • Purpose Evaluate contrast‐enhanced MRA injection strategies: measure r 1 , r 2 , and r 2 * of gadopiclenol, gadoterate meglumine, and gadoteridol in plasma and blood, and model arterial SI profiles for different injection rates.

Abstract

BACKGROUND: Gadolinium based contrast agents (GBCAs) vary in arterial signal intensity (SI) profiles. Gadopiclenol is a high relaxivity GBCA approved at 0.05 mmol/kg. PURPOSE: Evaluate contrast-enhanced MRA injection strategies: measure r1, r2, and r2* of gadopiclenol, gadoterate meglumine, and gadoteridol in plasma and blood, and model arterial SI profiles for different injection rates. STUDY TYPE: Phantom/Modeling. PHANTOM: Vials of oxygenated whole blood and plasma, with gadopiclenol, gadoterate meglumine, and gadoteridol ranging from 1 to 18 mM. FIELDSTRENGTH/SEQUENCE: Look-Locker, multi-echo turbo spin echo (mTSE), multi-echo fast field echo (mFFE) at 1.5 T and 3.0 T. ASSESSMENT: R1 derived by mono-exponential recovery fitting of Look-Locker data. R2 and R2* derived by fitting mono-exponential decays of mTSE and mFFE data. r1plasma, r2plasma,blood, r2plasma,blood* derived by linear fitting of R1, R2, R2* versus GBCA concentration [GBCA]. R1blood predicted using fast-exchange-regime (FXR) and -limit (FXL), compared with measured R1blood. Spoiled gradient echo (SPGR) SI versus [GBCA] modeled at 1.5 T and 3.0 T for each GBCA and two SPGR protocols using these blood relaxivities, generating SI versus time curves at rates of 0.5, 1, and 2 mL/s. STATISTICAL TESTS: Trust reflective least squares algorithm, Levenberg-Marquardt least squares curve fitting, FXR and FXL prediction models. RESULTS: Gadopiclenol r1plasma, r2plasma, r2plasma* ~3 times greater than gadoteridol and gadoterate meglumine. R1blood, well-predicted by FXR (RMSE 4.6 vs. 28 s-1 for FXL). Gadopiclenol r2blood* 20%-46% higher than the other contrast agents, with r2 blood similar across agents (7.4-8.8 s-1 mM-1 at 1.5 T and 12.9-13.4 s-1 mM-1 at 3.0 T). CE-MRA modeling demonstrated slight SI decrease at 1 versus 2 mL/s (0%-14% SI loss generally; 2%-6% for gadopiclenol), with a more uniform arterial enhancement profile. CONCLUSION: SI profiles vary for different GBCAs. Modeling showed injection rates as low as 1.0 mL/s (or 0.5 mL/s for gadopiclenol and gadobutrol) may provide benefit. TECHNICAL EFFICACY: Stage 3.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Predicting Signal Intensity Profiles for Various MRI Contrast Agent Injection Strategies: Including Measurement of Relaxivities in Oxygenated Whole Human Blood for Gadopiclenol, Gadoterate Meglumine and Gadoteridol — Science Skim