Evaluation of an acrylic acid hydrogel dosimeter for 3-D dose verification in radiotherapy using MRI
Ihssan S. Masad, Khalid A. Rabaeh, Samer I. Awad, Akram A. Almousa, Ahmed M. Masawi, M. Abdullah Al Kafi, Samer M. Alheet, Abdallah J. Nofal,
Gulf University for Science & Technology · Hashemite University
Key points
From the paper's conclusion- In conclusion, based on the analysis of R2-MRI maps, this study has demonstrated the reliability of using the novel (ACAGLPVA) hydrogel dosimeter as an accurate tool for 3-D verification of radiotherapy treatment plans.
Abstract
Gel dosimeters are commonly used to verify the dose distribution and consequently, ensure the accurate delivery of the dose as planned, which is very critical for the success of the radiotherapy. The current study aims to investigate the feasibility of using the magnetic resonance imaging (MRI)-based relaxation rate maps (R2 maps) of the novel acrylic acid with organic glucose polyvinyl alcohol (ACAGLPVA) hydrogel dosimeter for 3-D dose verification. The (ACAGLPVA) hydrogel was prepared and scanned with a 3-T MRI, prior to irradiation, using a spin-echo (SE) sequence. A series of 30 images with different echo times (TE) were acquired in order to generate R2 maps. The hydrogel was then irradiated with a maximum dose of 8 Gy using a CyberKnife system and the same MRI scans were acquired again for the irradiated gel phantom. The measured dose distributions obtained from R2-MRI maps were compared, using 2-D and 3-D Gamma analyses with 3% dose difference and 3-mm distance-to-agreement criteria, to those calculated from the treatment planning system (TPS). Results have shown high spatial agreement between the dose distributions calculated from TPS and the dose distributions derived from R2 maps, particularly in high-dose regions. The 3-D Gamma analysis achieved pass rates exceeding 90% across all planes for all evaluated dose levels-namely 90%, 70%, 50% and 20% of the maximum dose in the axial plane, as well as 90%, 70% and 50% of the maximum dose in the coronal and sagittal planes. In conclusion, based on the analysis of R2-MRI maps, this study has demonstrated the reliability of using the novel (ACAGLPVA) hydrogel dosimeter as an accurate tool for 3-D verification of radiotherapy treatment plans.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Development of a 3D Slicer Extension for MR-Based Gel Dosimetry AnalysisJournal of Physics: Conference Series · 2026
- Dosimetric Characterization Using Quantitative Magnetic Resonance Imaging of PAGAT and Gd-PAGAT Polymer Gel Dosimeters at High Gd Concentration.Gels (Basel, Switzerland) · 2026
- MRI Guided Radiotherapy using Deformable Gel DosimetryJournal of Physics: Conference Series · 2026
- Three-dimensional MRI-based FXO Gel Dosimetry for Verification of HDR Venezia Applicator Cervix BrachytherapyJournal of Physics: Conference Series · 2026
- Evaluation of the physical and radiological properties of different Fricke gel formulations as water-equivalent materials and biological tissues.Biomedical physics & engineering express · 2026
- Irradiation-induced modulation of T2 relaxation times in sucrose solutions: a novel externally controlled design strategy for quantitative magnetic resonance imaging phantoms.Radiological physics and technology · 2026