Interaction Between Access Cavity Design and NiTi Rotary Systems on Apical Debris Extrusion: An In Vitro Study.
Ayfer Atav, Burçin Arıcan, Esin Özlek, Ajinkya M Pawar
Department of Endodontics, Faculty of Dentistry, Istanbul Atlas University, 34408 Istanbul, Türkiye. · Department of Endodontics, School of Dental Medicine, Bahçeşehir University, 34353 Istanbul, Türkiye.
Key points
From the paper's conclusion- Results: There was a significant difference between both instrumentation systems and access cavity designs in terms of AED (p < 0.05).
Abstract
Background/Objectives: New-generation files and cavity designs may affect apical debris extrusion. This study compared the TruNatomy (TRN) and RaceEvo (REV) files regarding the amount of apically extruded debris (AED) of mandibular molars with different access cavity designs: Traditional Endodontic Cavity (TEC) and Contracted Endodontic Cavity (CEC). Methods: Sixty extracted mandibular molars with moderate mesial root curvature were divided into 4 groups (n = 15) according to the cavity design and instrumentation systems used: TEC/TRN; TEC/REV; CEC/TRN; and CEC/REV groups. The shaping of mesiobuccal canals was done at 37 °C, and irrigation was performed with bidistilled water. The AED was collected inside a glass jar and then desiccated for 5 days at 70 °C, with the amount of AED calculated by weighing jars. A two-way analysis of variance and the Bonferroni test were used for the statistical analysis of the data, with the significance level set at p < 0.05. Results: There was a significant difference between both instrumentation systems and access cavity designs in terms of AED (p < 0.05). The highest mean value was obtained in the TEC-TRN group, and the lowest mean value was obtained in the CEC-REV group. The REV file system caused significantly less AED than TRN within the TEC design; no significant difference was found between file systems within the CEC design (p > 0.05). Conclusions: The TEC and the TRN system were associated with a higher AED. Clinical Significance: The CEC would be a good choice in the clinic to decrease AED.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The Impact of Access Cavity Design in Combination with Rotation and Reciprocation File Systems on Pericervical Dentin Preservation and Instrumentation Efficiency: An In Vitro Study.Dentistry journal · 2026
- Comparative Assessment of Observed Dentinal Defects Following Root Canal Preparation With TruNatomy, ProTaper Next, and Dia-X Nickel-Titanium Rotary Systems: An In Vitro Study.International journal of dentistry · 2026
- Shaping ability of TruNatomy, i-File X, and ProTaper Universal in mesial canals of 3D-printed mandibular molars: a micro-CT study.BMC oral health · 2026
- Efficacy of a single-file reciprocating protocol vs. a multi-file rotary protocol on the removal of gutta-percha and ceraSeal sealer from oval canals: a volumetric and active instrumentation time analysis.Frontiers in dental medicine · 2026
- Cyclic Fatigue Resistance and Fractured Fragment Length of Three NiTi Rotary Systems: An In Vitro ComparisonOral · 2026
- Comparison of post-operative pain between rotary and reciprocating file systems in root canal therapy: An in vivo study.Bioinformation · 2026