Efficacy of a single-file reciprocating protocol vs. a multi-file rotary protocol on the removal of gutta-percha and ceraSeal sealer from oval canals: a volumetric and active instrumentation time analysis.
Ahmed Zorek, Abeer H Mahran, Mohammed Nabeel, Tarek Elsewify
Endodontic Department, Misr International University, Cairo, Egypt. · Endodontic Department, Ain Shams University, Cairo, Egypt.
Key points
From the paper's conclusion- Objective To evaluate and compare the overall efficacy and time efficiency of two complete manufacturer-recommended retreatment protocols, a single-file reciprocating protocol, Reciproc (RC), vs. a multi-file continuous rotary protocol, ProTaper Universal Retreatment (PR), in removing gutta-percha and CeraSeal sealer from oval-shaped root canals.
Abstract
OBJECTIVE: To evaluate and compare the overall efficacy and time efficiency of two complete manufacturer-recommended retreatment protocols, a single-file reciprocating protocol, Reciproc (RC), vs. a multi-file continuous rotary protocol, ProTaper Universal Retreatment (PR), in removing gutta-percha and CeraSeal sealer from oval-shaped root canals. METHODOLOGY: Thirty-six single-rooted human mandibular premolars with single oval canals were selected, instrumented, and obturated with a matching cone gutta-percha and CeraSeal sealer. Initial filling volumes were evaluated via CBCT. The samples were randomly divided into two experimental groups (n = 18) according to the file used for retreatment. The net active instrumentation time was recorded. Post-retreatment CBCT scans were performed to measure the volume and percentage of remaining filling materials. Data were statistically analyzed at a significance level of p ≤ 0.05. RESULTS: Both systems significantly reduced the filling volume (p < 0.0001). No significant difference was found in the initial filling volumes between groups (p = 0.616). However, the RC group demonstrated a significantly lower mean volume (0.474 ± 0.313 mm3) and percentage (5.52 ± 1.97%) of remaining filling material compared to the PR group (1.735 ± 0.753 mm3 and 20.72 ± 2.93%, respectively; p < 0.0001). Furthermore, the RC group required significantly less active instrumentation time (48.69 ± 4.98 s) than the PR group (68.49 ± 5.43 s, p < 0.0001). CONCLUSION: Within the limitations of this in vitro study, neither mechanical retreatment protocol completely removed CeraSeal sealer and gutta-percha from oval root canals. However, the single-file RC protocol was significantly more effective and time-efficient than the multi-file PR protocol. The superior performance of the RC protocol reflects the combined effect of its matched apical size (size 40 vs. size 20), single-file sequence, cross-sectional design, and reciprocating kinematics, rather than kinematic motion alone.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of post-operative pain between rotary and reciprocating file systems in root canal therapy: An in vivo study.Bioinformation · 2026
- Comparative In Vitro Assessment of Original Reciproc® Blue Instruments vs. Two Replicas: Mechanical Characteristics, Safety, and Efficacy AnalysisOral · 2026
- The Impact of Access Cavity Design in Combination with Rotation and Reciprocation File Systems on Pericervical Dentin Preservation and Instrumentation Efficiency: An In Vitro Study.Dentistry journal · 2026
- Removal of overextended root canal filling beyond the apex in lower premolar teeth using two different retreatment rotary files versus manual files: a comparative in vitro study.BMC oral health · 2026
- Interaction Between Access Cavity Design and NiTi Rotary Systems on Apical Debris Extrusion: An In Vitro Study.Dentistry journal · 2026
- Choosing the Right File for the Canal: Clinical Applications of Two Different Single-File Reciprocating Systems.Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995) · 2026