From Digital Deviation to Clinical Fit: Do Inter-Scanner Discrepancies Predict Passive-Fit Differences in Full-Arch Implant Rehabilitation?
Alessandro Agnini, Andrea Agnini, Tommaso Weinstein, Tommaso Matteucci, Giulia Benedetti, Mario Imburgia
Private Practice, Modena and Sassuolo, Italy, specializing in fixed prosthodontics, periodontology, and implant dentistry; Founding Member, Italian Society of Prosthodontics and Oral Rehabilitation. · Private Practice, Modena and Sassuolo, Italy, specializing in fixed prosthodontics, periodontology, and implant dentistry.
Key points
From the paper's conclusion- The findings suggest that the clinical significance of a digital discrepancy may depend not only on its magnitude but also its spatial distribution and location within the arch.
Abstract
Digital accuracy in complete-arch implant impressions is commonly evaluated through numerical measurements of trueness, precision, and 3-dimensional deviation. However, the clinical significance of these measurements is not clearly understood: a measurable digital discrepancy does not necessarily indicate that a prosthetic framework will demonstrate clinically detectable misfit. This exploratory in vivo investigation examined the relationship between relative inter-scanner deviations and the passive fit of corresponding verification bars in four full-arch implant-supported rehabilitations. Definitive digital impressions were obtained during the same clinical session using four intraoral scanning systems based on different acquisition technologies. The resulting datasets were anonymized and compared through 3-dimensional superimposition to characterize relative inter-device agreement. A standardized CAD/CAM aluminum verification bar was then fabricated from each dataset and evaluated clinically and radiographically by blinded operators using rocking assessment, the one-screw (Sheffield) test, passive screw insertion, and radiographic verification. Measurable relative deviations ranging from approximately 20 μm to 80 μm were identified, with discrepancies predominantly concentrated at terminal implant positions and along the vertical axis. Digital deviation magnitude alone, however, did not consistently predict clinically detectable passive-fit differences. The findings suggest that the clinical significance of a digital discrepancy may depend not only on its magnitude but also its spatial distribution and location within the arch. Within the limitations of this exploratory investigation, these observations reinforce the importance of interpreting digital accuracy data in conjunction with clinical prosthetic verification when evaluating complete-arch implant workflows.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Accuracy of 12 Intraoral Scanners and Photogrammetric Systems for Full-Arch Edentulous Maxillae: An In Vitro Study.The International journal of periodontics & restorative dentistry · 2026
- The Accuracy of Digital vs Conventional Impression among Patients Receiving Dental Implants: A Systematic Review and Meta Analysis of Clinical Studies : Short title: Digital vs Conventional Impression among Patients Receiving Dental Implants.Galen medical journal · 2026
- Linear and Angular Deviations of Complete-Arch Digital Implant Impressions Using Three Scan Body Systems: An In Vitro Study.Dentistry journal · 2026
- Accuracy and clinical passive fit of reverse and standard scan body protocols for complete-arch implant-supported digital impressions: An in vitro study.Journal of prosthodontics : official journal of the American College of Prosthodontists · 2026
- Interimplant distance and angulation measurement from CAD-generated multiunit abutment interfaces: A scan body-independent technique.The Journal of prosthetic dentistry · 2026
- Accuracy is a behavior, not a number: a metrological reporting framework for complete-arch implant scanningJournal of Dentistry · 2026