Compendium of continuing education in dentistry (Jamesburg, N.J. : 1995)

From Digital Deviation to Clinical Fit: Do Inter-Scanner Discrepancies Predict Passive-Fit Differences in Full-Arch Implant Rehabilitation?

Alessandro Agnini, Andrea Agnini, Tommaso Weinstein, Tommaso Matteucci, Giulia Benedetti, Mario Imburgia

Private Practice, Modena and Sassuolo, Italy, specializing in fixed prosthodontics, periodontology, and implant dentistry; Founding Member, Italian Society of Prosthodontics and Oral Rehabilitation. · Private Practice, Modena and Sassuolo, Italy, specializing in fixed prosthodontics, periodontology, and implant dentistry.

Key points

From the paper's conclusion
  • The findings suggest that the clinical significance of a digital discrepancy may depend not only on its magnitude but also its spatial distribution and location within the arch.

Abstract

Digital accuracy in complete-arch implant impressions is commonly evaluated through numerical measurements of trueness, precision, and 3-dimensional deviation. However, the clinical significance of these measurements is not clearly understood: a measurable digital discrepancy does not necessarily indicate that a prosthetic framework will demonstrate clinically detectable misfit. This exploratory in vivo investigation examined the relationship between relative inter-scanner deviations and the passive fit of corresponding verification bars in four full-arch implant-supported rehabilitations. Definitive digital impressions were obtained during the same clinical session using four intraoral scanning systems based on different acquisition technologies. The resulting datasets were anonymized and compared through 3-dimensional superimposition to characterize relative inter-device agreement. A standardized CAD/CAM aluminum verification bar was then fabricated from each dataset and evaluated clinically and radiographically by blinded operators using rocking assessment, the one-screw (Sheffield) test, passive screw insertion, and radiographic verification. Measurable relative deviations ranging from approximately 20 μm to 80 μm were identified, with discrepancies predominantly concentrated at terminal implant positions and along the vertical axis. Digital deviation magnitude alone, however, did not consistently predict clinically detectable passive-fit differences. The findings suggest that the clinical significance of a digital discrepancy may depend not only on its magnitude but also its spatial distribution and location within the arch. Within the limitations of this exploratory investigation, these observations reinforce the importance of interpreting digital accuracy data in conjunction with clinical prosthetic verification when evaluating complete-arch implant workflows.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers