Measurement Reliability and Trial-Sampling Effects in Ultrasound Assessment of Abdominal Muscle Thickness During the Active Straight Leg Raise
Yinghong Liu, Xiaoliang Qiu, Dae-Sung Park
Key points
From the paper's conclusion- Background/Objectives: This secondary analysis of a previously published cohort addressed four measurement questions:: variability from repeated caliper placement on the same image, change-score reliability across active straight leg raise (ASLR) trials, sensitivity to trial selection, and reproducibility of delayed rereading of stored images Methods: Thirty-three healthy adults completed three pa
Abstract
Background/Objectives: This secondary analysis of a previously published cohort addressed four measurement questions:: variability from repeated caliper placement on the same image, change-score reliability across active straight leg raise (ASLR) trials, sensitivity to trial selection, and reproducibility of delayed rereading of stored images Methods: Thirty-three healthy adults completed three paired rest–ASLR trials under relaxed, maximal dorsiflexion, and maximal plantarflexion conditions. The dataset contained 594 stored images, each measured three times for each of the transversus abdominis (TrA), internal oblique (IO), and external oblique (EO). Fifty images from 11 participants were reread by the same examiner 15 days after the original assessment, as reported in the parent publication. Results: Mean within-image SDs were 0.143, 0.231, and 0.185 mm for TrA, IO, and EO. The pooled single-trial TrA change-score intraclass correlation coefficient [ICC(A,1)] was 0.629 (95% CI, 0.431–0.760); model-projected ICCs for averages of two and three complete trials were 0.772 (95% CI, 0.603–0.864) and 0.836 (95% CI, 0.695–0.905), respectively. The complete-trial dorsiflexion-minus-relaxed TrA contrast was 0.162 mm (95% CI, 0.059–0.265); plantarflexion-minus-relaxed was 0.085 mm (95% CI, −0.022–0.193). Estimates based on different trial subsets varied, particularly for the plantarflexion contrast. Delayed rereading ICC(A,1) values were 0.819 (TrA), 0.893 (IO) and 0.848 (EO).Absolute differences were larger than would be expected from immediate caliper dispersion alone. Conclusions: Caliper-placement variability, reliability across ASLR trials, sensitivity to trial selection, and delayed rereading of stored images represent distinct measurement properties and should not be conflated. Trial-averaging values were conditional model projections rather than validated clinical recommendations, and this study did not assess diagnostic validity or repeat-scan reliability.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of ultrasonography for transversus abdominis and lumbar multifidus thickness in participants with and without low back painBMC Musculoskeletal Disorders · 2026
- Intra- and Inter-Rater Reliability of Inter-Recti Distance Measurement Using B-Mode and Panoramic Ultrasound ImagingJournal of Clinical Medicine · 2026
- Standardizing Ankle Position During the Active Straight Leg Raise: Effects on Lateral Abdominal Muscle Thickness and Pressure Biofeedback in Healthy Young Adults.Journal of functional morphology and kinesiology · 2026
- Reliability of shear wave elastography measurements of the linea alba: an intraclass correlation and Bland-Altman analysis.BMC women's health · 2026
- Inter- and Intra-Rater Reliability of Ultrasound Measurement of the Anterior Talofibular Ligament in Adult WomenSensors · 2026
- Reliability of Offline Measurements of Stored Transperineal Ultrasound Images: An Exploratory Analysis by Observer Experience.International urogynecology journal · 2026