Reliability of Offline Measurements of Stored Transperineal Ultrasound Images: An Exploratory Analysis by Observer Experience.
Ting Xiao, Yunqing Cao, Siyun Du, Zhuoru Luo, Weijun Huang
Ultrasound Diagnosis and Treatment Centre, The First People's Hospital of Foshan (Foshan Hospital Affiliated to Southern University of Science and Technology), Foshan, 528000, China. · Ultrasound Diagnosis and Treatment Centre, The First People's Hospital of Foshan (Foshan Hospital Affiliated to Southern University of Science and Technology), Foshan, 528000, China. hwjun1716@163.com.
Key points
From the paper's conclusion- Interobserver reliability of offline measurements of stored TPUS images was highest for BP and BND and lowest for RVA. In exploratory analyses, reliability estimates for URA and RVA were lower among junior observers, whereas BP and BND remained highly reliable.
Abstract
INTRODUCTION AND HYPOTHESIS: Previous studies have evaluated the reproducibility of transperineal ultrasound (TPUS) parameters for stress urinary incontinence (SUI); however, their relative reliability remains incompletely characterized. We aimed to evaluate inter- and intra-observer reliability of four TPUS parameters measured offline on stored images and explore differences by observer experience. METHODS: This retrospective study included 398 women who underwent TPUS 6-8 weeks postpartum. Four observers, all radiologists (two senior and two junior), independently assessed four parameters: bladder position (BP), bladder neck descent (BND), urethral rotation angle (URA), and retrovesical angle (RVA) on stored dynamic midsagittal cine loops. Measurements were repeated after 2 weeks using the same image dataset. Reliability was assessed using intraclass correlation coefficients (ICCs), standard error of measurement (SEM), minimal detectable change (MDC95), and Bland-Altman analysis; analyses stratified by observer experience were exploratory. RESULTS: Interobserver ICCs were highest for BP 0.981 (95% CI 0.965-0.988) and BND 0.977 (0.971-0.982), lower for URA 0.850 (0.827-0.871), and lowest for RVA 0.694 (0.653-0.733). SEM/MDC95 were 1.33/3.68 mm for BP, 1.43/3.96 mm for BND, 9.69/26.87° for URA, and 13.69/37.94° for RVA. Stratified by observer experience, ICC estimates for URA and RVA were lower among junior observers, whereas BP and BND remained high in both groups. CONCLUSIONS: Interobserver reliability of offline measurements of stored TPUS images was highest for BP and BND and lowest for RVA. In exploratory analyses, reliability estimates for URA and RVA were lower among junior observers, whereas BP and BND remained highly reliable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Transperineal Ultrasound for Preoperative Pelvic Floor Assessment Prior to Radical Prostatectomy: Inter-Operator Reliability and Concordance With Magnetic Resonance Imaging.Archivos espanoles de urologia · 2026
- Transrectal Biplane Ultrasound Combined with Cotton Swab Marking of the External Urethral Orifice for Evaluating the Postoperative Position of Transobturator Mid-Urethral Sling: A Study on Standardized Ultrasound Measurement and Inter-Observer Reliability.Diagnostics (Basel, Switzerland) · 2026
- Post-Surgical Evaluation in Stress Urinary Incontinence by Transperineal Ultrasound and Quality of Life Questionnaire-A Retrospective Study.Diagnostics (Basel, Switzerland) · 2026
- Measurement Reliability and Trial-Sampling Effects in Ultrasound Assessment of Abdominal Muscle Thickness During the Active Straight Leg RaiseDiagnostics · 2026
- Intra- and Inter-Rater Reliability of Inter-Recti Distance Measurement Using B-Mode and Panoramic Ultrasound ImagingJournal of Clinical Medicine · 2026
- Prostate volume on transrectal ultrasound: comparing ultrasounds performed by urologists to radiologists.The Canadian journal of urology · 2026