Inter- and Intra-Rater Reliability of Ultrasound Measurement of the Anterior Talofibular Ligament in Adult Women
Ana-Belen Ortega-Avila, Violeta Lopez-Garcia, Sandra Sanchez-Morilla, Pablo Cervera-Garvi
Key points
From the paper's conclusion- Background: Despite the growing use of musculoskeletal ultrasound for anterior talofibular ligament (ATFL) assessment, there is limited evidence regarding the reliability of standardized measurement protocols, particularly in adult women.
Abstract
Background: Despite the growing use of musculoskeletal ultrasound for anterior talofibular ligament (ATFL) assessment, there is limited evidence regarding the reliability of standardized measurement protocols, particularly in adult women. In addition, the reliability of combined morphological measurements, including thickness, length and two-dimensional area, remains unclear. The objective of this study is to evaluate the intra- and inter-rater reliability of ultrasound measurements of ATFL. Methods: This reliability and concordance study included 20 ankles from 10 women aged 40–65 years, recruited from a university clinical unit. Two examiners—one experienced and one novice, trained in musculoskeletal ultrasound—independently measured ATFL morphology using a standardized protocol. Each examiner performed three repeated measurements per foot across three sessions. Statistical analyses included intraclass correlation coefficients (ICC), Cronbach’s α, concordance correlation coefficients (CCC), standard error of measurement (SEM), and Bland–Altman plots. Results: ICC values were high for both RF (0.774–0.991) and LF (0.933–0.983). Inter-rater agreement was also excellent, with ICC for thickness, length and area of 0.913, 0.967 and 0.997 in RF, and 0.934, 0.895 and 0.985 in LF, respectively. Bland–Altman analysis revealed minimal mean bias and narrow limits of agreement, especially for thickness (−0.220 to 0.200 mm). CCC values (0.917–0.992) further supported these findings, along with low SEM values across all variables. Conclusions: Ultrasound provides robust, precise, and reproducible measurements of ATFL morphology in adult women when performed under standardized conditions. These findings provide a methodological basis for future studies investigating its diagnostic and longitudinal clinical utility.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reliability of sonographic measurements of anterior talofibular ligament band thickness.Ultrasound (Leeds, England) · 2026
- Accuracy of ultrasound in diagnosing anterior talofibular ligament injury: a meta-analysis.Langenbeck's archives of surgery · 2026
- Ultrasound identification and sonoanatomy of the inferior fascicle of the anterior talofibular ligament: a cadaveric study.Journal of ultrasound · 2026
- Relative and absolute reliability of medial knee joint space width measurement using ultrasound imaging during valgus stress testing.PloS one · 2026
- Inter-examiner and inter-day reliability of dynamic tibiofemoral movements measurement using motion capture during walking and jumping tasksThe Knee · 2026
- Reliability of Ultrasound Measurements in the Assessment of Femoral Trochlear Morphology in Healthy AdolescentsDiagnostics · 2026