Inter- and Intra-Rater Reliability of Ultrasound Measurement of the Anterior Talofibular Ligament in Adult Women

Ana-Belen Ortega-Avila, Violeta Lopez-Garcia, Sandra Sanchez-Morilla, Pablo Cervera-Garvi

Key points

From the paper's conclusion
  • Background: Despite the growing use of musculoskeletal ultrasound for anterior talofibular ligament (ATFL) assessment, there is limited evidence regarding the reliability of standardized measurement protocols, particularly in adult women.

Abstract

Background: Despite the growing use of musculoskeletal ultrasound for anterior talofibular ligament (ATFL) assessment, there is limited evidence regarding the reliability of standardized measurement protocols, particularly in adult women. In addition, the reliability of combined morphological measurements, including thickness, length and two-dimensional area, remains unclear. The objective of this study is to evaluate the intra- and inter-rater reliability of ultrasound measurements of ATFL. Methods: This reliability and concordance study included 20 ankles from 10 women aged 40–65 years, recruited from a university clinical unit. Two examiners—one experienced and one novice, trained in musculoskeletal ultrasound—independently measured ATFL morphology using a standardized protocol. Each examiner performed three repeated measurements per foot across three sessions. Statistical analyses included intraclass correlation coefficients (ICC), Cronbach’s α, concordance correlation coefficients (CCC), standard error of measurement (SEM), and Bland–Altman plots. Results: ICC values were high for both RF (0.774–0.991) and LF (0.933–0.983). Inter-rater agreement was also excellent, with ICC for thickness, length and area of 0.913, 0.967 and 0.997 in RF, and 0.934, 0.895 and 0.985 in LF, respectively. Bland–Altman analysis revealed minimal mean bias and narrow limits of agreement, especially for thickness (−0.220 to 0.200 mm). CCC values (0.917–0.992) further supported these findings, along with low SEM values across all variables. Conclusions: Ultrasound provides robust, precise, and reproducible measurements of ATFL morphology in adult women when performed under standardized conditions. These findings provide a methodological basis for future studies investigating its diagnostic and longitudinal clinical utility.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers