Assessment of Carotid Siphon Pulsatility Index via Transorbital Window, an Alternative for Intracranial Measurements.
Oswaldo Andrés Bolaños Ladinez, Geovanny Gabriel Garcia Cox, Paula Olivos Massa, Maria Gabriela de la Cruz Novoa, Fernando Roosemberg, Sérgio Brasil
Hospital Clínica San Francisco, Av. Alejandro Andrade Coello 98, Guayaquil 090512, Ecuador. · Department of Intensive Care, Hospital General Dr. Enrique Ortega Moreira, Via Durán Km 2.5, Guayaquil 092408, Ecuador.
Key points
From the paper's conclusion- Conclusions: In this cohort of neurocritical patients, the carotid siphon pulsatility index showed a strong correlation with the middle cerebral artery pulsatility index, suggesting concordant hemodynamic behavior between both sites of insonation and supporting the potential of the carotid siphon as an alternative for Doppler evaluation when the acoustic window is limited.
Abstract
Objective: To analyze the correlation between the hemodynamic indices of the carotid siphon (CS), the middle cerebral artery (MCA) and the optic nerve sheath diameter (ONSD) among patients with acute brain injuries. Materials and methods: An observational, analytical, and cross-sectional study was conducted. Pulsatility indices (PI) of the CS and MCA were recorded using transcranial Doppler, and ONSD was measured using ocular ultrasound. Pearson's and Spearman's correlation coefficients were applied, considering statistical significance at p < 0.005. Results: A total of 75 neurocritical patients were enrolled during 2024. A strong positive correlation was observed between the CS PI and the MCA PI, in both the right (r = 0.643; p < 0.001) and left (r = 0.702; p < 0.001) hemispheres. A weak but significant positive correlation was found between the left CS PI and left ONSD (r = 0.242; p = 0.039). Patients with a PI greater than 1.2 had a larger ONSD than those with a PI of 1.2 or lower (t = -2.29; p = 0.025). The mean difference was approximately 0.44 mm, based on the 95% confidence interval from -0.830 to -0.057. This association was observed only in the left hemisphere and showed a moderate effect size (Cohen's d = -0.61). Conclusions: In this cohort of neurocritical patients, the carotid siphon pulsatility index showed a strong correlation with the middle cerebral artery pulsatility index, suggesting concordant hemodynamic behavior between both sites of insonation and supporting the potential of the carotid siphon as an alternative for Doppler evaluation when the acoustic window is limited. An optic nerve sheath enlargement may be associated with higher pulsatility index; however, invasive ICP monitoring is needed to evaluate the reliability of this association.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Noninvasive Intracranial Pressure Monitoring in Pediatric Traumatic Brain Injury: Systematic Review of Transcranial Doppler and Optic Nerve Sheath Diameter With Identification of an Evidence Gap in Pupillometry.Pediatric neurology · 2026
- Regional Perivascular Space Burden in Pediatric Idiopathic Intracranial Hypertension: A Case-Control MRI Study.Diagnostics (Basel, Switzerland) · 2026
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026
- Ultrasound assessment of the optic nerve sheath diameter in adult patients with suspected intracranial hypertension: A scoping review.Australian critical care : official journal of the Confederation of Australian Critical Care Nurses · 2026
- Effect of Eye Movement and Body Position on Optic Nerve Sheath Width.Journal of ophthalmic & vision research · 2026
- Limited utility of optic nerve sheath diameter for monitoring intracranial pressure in patients with intracranial hemorrhage.Frontiers in neurology · 2026