Orthopedic Biomaterials in the Clinical Reconstruction of Osteoporotic Atlantoaxial Injuries: A Review.
Xiaohu Zhang, Jie Liu, Zilin Gao, Xiaohui Wang
Honghui Hospital, Xi'an Jiaotong University, Xi'an 710054, China.
Key points
From the paper's conclusion- Patient-specific porous degradable screws, which combine 3D-printed biomaterials, gradient alloys, and sustained-release bioactive coatings, represent a promising future research direction. This review provides theoretical support for the development of atlantoaxial internal fixation devices targeting elderly osteoporotic patients.
Abstract
BACKGROUND: Aging of the population increases the incidence of osteoporosis with atlantoaxial instability. Poor bone microarchitecture causes high rates of screw loosening, implant failure, and revision surgery, which remains a critical challenge for upper cervical surgery. Traditional atlantoaxial fixation is less effective in those with low bone mineral density, while thoracolumbar screw augmentation techniques are limited by the complex craniocervical anatomy. METHODS: This review systematically summarizes the mainstream screw optimization strategies from a bioengineering perspective, including low-modulus alloy substrate modification, bionic threaded structural design, bioactive surface coatings, expandable screws, and cement-augmented cannulated screws. We compare the biomechanical anchorage performance, osteogenic capacity, and clinical complications of each technique. RESULTS: Low-elastic-modulus titanium alloys reduce stress shielding; gradient multi-thread, bicortical, and CBT trajectory designs significantly improve anti-pullout stability; HA, tantalum, and composite extracellular matrix coatings promote osseointegration; and expandable screws and fenestrated cement screws can achieve reliable reinforcement. However, a narrow atlantoaxial space restricts the application of cement augmentation and expandable implants, and long-term, large-sample clinical evidence for the efficacy of novel screws is insufficient. CONCLUSION: Patient-specific porous degradable screws, which combine 3D-printed biomaterials, gradient alloys, and sustained-release bioactive coatings, represent a promising future research direction. This review provides theoretical support for the development of atlantoaxial internal fixation devices targeting elderly osteoporotic patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Performance-sensitivity analysis of atlantoaxial fixation constructs using finite element modelling.Journal of the mechanical behavior of biomedical materials · 2026
- A Novel Semi-Cannulated Screw with Cement Augmentation for Revision Lateral Mass Fixation: A Cyclic Loading Biomechanical Study.Acta orthopaedica Belgica · 2026
- Comparison of an anchor plate with suture anchor and transosseous constructs for rotator cuff repair in a polyurethane foam block: a biomechanical studyBMC Musculoskeletal Disorders · 2026
- Asymmetric metaphyseal cones versus medial modular block augment with central cone for medial tibial defects : a biomechanical comparison in varying bone quality.Bone & joint research · 2026
- Allograft Strut Fixation to Humeral Bone: A Biomechanical Comparison of Suture-Tape Cerclage, Wire Cerclage, and Screws.Journal of shoulder and elbow surgery · 2026
- A novel stiffness-distribution-controlled hybrid locking compression plate for osteoporotic midshaft clavicle fractures: a finite element study.BMC musculoskeletal disorders · 2026