Asymmetric metaphyseal cones versus medial modular block augment with central cone for medial tibial defects : a biomechanical comparison in varying bone quality.
Yi Ren, Chloe E H Scott, Nick D Clement, Shuqiao Xie, Pankaj Pankaj
Institute for Bioengineering, School of Engineering, The University of Edinburgh, Edinburgh, UK. · Edinburgh Orthopaedics, Royal Infirmary of Edinburgh, Edinburgh, UK.
Key points
From the paper's conclusion- Asymmetric cones are viable in good bone stock but exhibit instability in osteoporosis due to the cantilever effect. Anatomical reconstruction with a modular augment and central cone provides a predictable, load-sharing structural column, making it the preferred strategy for large medial defects in osteoporotic patients.
Abstract
AIMS: Managing large medial tibial bone defects during total knee arthroplasty (TKA) remains technically demanding, particularly in elderly patients. This study quantitatively compares two reconstructive strategies: 'bridging' the defect using an asymmetric metaphyseal cone versus 'anatomical reconstruction' employing a symmetrical cone with a metallic block augment, and assesses their sensitivity to osteoporotic bone quality. METHODS: A finite element model of a tibia with a standardized medial defect (Anderson Orthopaedic Research Institute (AORI) Type 2a) was adapted to simulate both configurations under physiological loading cycles in healthy and severe osteoporotic bone. Cumulative interface micromotion was quantified using a coordinate-based post-processing algorithm that decouples normal separation from tangential shear. A parametric sweep of the tangential contact clearance evaluated near-surface biological interaction zones without additional simulations. RESULTS: In healthy bone, both strategies demonstrated adequate stability with micromotions predominantly below 50 μm. In osteoporotic bone, the asymmetric cone exhibited a loss of stability, characterized by intermittent lift-off during walking and excessive tangential shear during stair descending. This instability induced a toggle effect at the distal stem. The augmented symmetrical cone maintained stable fixation regardless of bone quality. Expanding the tangential contact clearance revealed considerable unrecognized shear risk surrounding the asymmetric cone, while the augmented construct remained insensitive to this parameter in the high-risk range (> 100 μm). CONCLUSION: Asymmetric cones are viable in good bone stock but exhibit instability in osteoporosis due to the cantilever effect. Anatomical reconstruction with a modular augment and central cone provides a predictable, load-sharing structural column, making it the preferred strategy for large medial defects in osteoporotic patients.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Asymmetric Metaphyseal Cones for AORI Type 2 Medial Defects in Tibial Plateau Fractures during Acute TKAJournal of Orthopaedic Research® · 2026
- A novel strategy for reconstruction of AORI type III proximal tibial defects : surface-type knee reconstruction following defect reconstruction with 3D-printed extension-stem augment.Bone & joint research · 2026
- Native varus angle does not affect the primary fixation of cementless TKA using kinematic alignment - A population-based FE study.Journal of biomechanics · 2026
- Biomechanical Study of the Preventive Effect of Different Cephalomedullary Fixation Methods on the Occurrence of Femoral Neck Fractures in Osteoporotic Femurs.Medicina (Kaunas, Lithuania) · 2026
- Axial Stiffness Advantage of Nail–Plate Fixation in 101 Patient-Specific Femora: A Finite Element StudyJournal of Clinical Medicine · 2026
- CT-based 3D planning-supported stem-free screw-cement augmentation versus 2D radiograph-planned short-stem reconstruction for AORI type I–II medial tibial defects in TKA: a two-year retrospective studyJournal of Orthopaedic Surgery and Research · 2026