A Novel Semi-Cannulated Screw with Cement Augmentation for Revision Lateral Mass Fixation: A Cyclic Loading Biomechanical Study.
Canyang Huang, Zhiping Huang, Zhenqiang Wang, Xiuhua Wu, Qingan Zhu, Dongbin Qu
Key points
From the paper's conclusion- The novel semi-cannulated lateral mass screw with cement augmentation demonstrated superior dynamic stability and significantly improved fixation strength after cyclic loading compared to conventional solid screws, offering a promising revision strategy for cervical spines with screw loosening or osteoporosis.
Abstract
UNLABELLED: Dongbin Qu, Division of Spine Surgery, Department of Orthopaedics, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong 510000, P. R. China. Email: nfyy_qu@126.com Canyang Huang, Division of Spine Surgery, Department of Orthopaedics, Quanzhou First Hospital Affiliated to Fujian Medical University, Quanzhou, Fujian 362000, P. R. China. Email: huangcy0595@sina.com Purpose: This study biomechanically compared a novel semi-cannulated lateral mass screw with cement augmentation against conventional solid screws for stabilizing loosened cervical lateral masses under cyclic loading. METHODS: Eight fresh human cervical specimens underwent μCT scanning for BMD assessment. Each specimen received both screw types: on the augmentation side, semi-cannulated screws were initially loosened via pull-out testing then reinserted with cement; on the (contralateral) primary side, conventional solid screws were placed Awithout augmentation. After cyclic loading, vertical displacement, toggling angle, and rotation center distance (ORC) at the screw-bone interface were measured, followed by final pull-out force tests. RESULTS: The mean BMD of the lateral masses was 305.05 ± 48.33 mg/cm³. Following cyclic loading, the augmentation side exhibited a significantly higher pull-out force than its initial state (P < 0.01), though not statistically greater than the primary side. Under cyclic loading, the augmentation side demonstrated significantly superior stability: vertical displacement increased by only 6.25%, compared to a 70.69% increase on the primary side (P < 0.05). The toggling angle decreased by 2.36% on the augmentation side, versus a significant 79.92% increase on the primary side (P < 0.05). The ORC increased by 2.13% on the augmentation side, markedly lower than the 38.03% increase on the primary side. CONCLUSION: The novel semi-cannulated lateral mass screw with cement augmentation demonstrated superior dynamic stability and significantly improved fixation strength after cyclic loading compared to conventional solid screws, offering a promising revision strategy for cervical spines with screw loosening or osteoporosis.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Biomechanical Comparison of Composite versus Screw-Rod Fixation for Posterior C5-C6 Fusion.Global spine journal · 2026
- BIOMECHANICAL STUDY OF PULLOUT RESISTANCE OF CORTICAL SCREWS IN SWINE LUMBAR VERTEBRAE.Acta ortopedica brasileira · 2026
- Biomechanical effects of lateral pedicle wall violation and subsequent screw redirection on pedicle screw anchorage.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Biomechanical Study of the Preventive Effect of Different Cephalomedullary Fixation Methods on the Occurrence of Femoral Neck Fractures in Osteoporotic Femurs.Medicina (Kaunas, Lithuania) · 2026
- Fixation of Zone 2 Sacral Fractures Utilizing a Novel Compressive Bolt - A Biomechanical Comparison.Journal of orthopaedic trauma · 2026
- Patient Selection and Reoperation After Cement-Augmented Pedicle Screw Fixation in the Thoracolumbar Spine: A Single-Center Cohort.Journal of clinical medicine · 2026