A Novel Titanium End-Disc-Assisted Allograft Preparation System for Anterior Cervical Corpectomy and Fusion: Development and Preliminary Biomechanical Evaluation.
Chih-Chang Chang, Shao-Fu Huang, Pin-Cang Huang, Chun-Li Lin
Department of Biomedical Engineering, National Yang Ming Chiao Tung University, Taipei 112201, Taiwan.
Key points
From the paper's conclusion- Conclusions: The proposed system enabled standardized graft preparation and construct assembly.
Abstract
Background: Allograft bone remains an attractive option for anterior cervical corpectomy and fusion (ACCF), but its use can be limited by variable graft geometry, insufficient endplate contact, and operator-dependent trimming. This study aimed to develop a titanium end-disc-assisted allograft construct with a standardized cutting and assembly system and to preliminarily evaluate its static mechanical integrity under axial compression, compression-shear, and torsional loading. Methods: The construct consisted of a controlled-length bone graft, two Ti6Al4V end-discs, and four countersunk fixation screws, forming a graft-disc construct with a maximum total height not exceeding 40 mm. The end-discs incorporated angled screw holes, bone-graft filling spaces, and enlarged contact surfaces. A modular preparation system was designed for graft clamping, length definition, guided cutting, alignment, pre-drilling, and screw fixation. Porcine rib specimens were used as an allograft substitute. Native bone and assembled constructs were tested under static compression, compression-shear, and torsion. Results: The system produced standardized constructs. Except for axial compressive stiffness, the assembled constructs showed numerically higher compressive yield force, shear stiffness, shear yield force, torsional stiffness, and yield torque than native bone; however, these findings were interpreted descriptively because of the limited sample size. Failure occurred mainly within the bone, with no obvious failure at the bone-titanium interface, titanium end-discs, or fixation screws. Conclusions: The proposed system enabled standardized graft preparation and construct assembly. Further fatigue, subsidence, and clinically relevant cervical spine model testing are required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and biomechanical validation of a zero-profile self-stabilizing 3D-printed titanium mesh cage for anterior cervical corpectomy and fusionFrontiers in Bioengineering and Biotechnology · 2026
- Influence of anterior plate fixation on axial load-bearing capacity after single-level anterior cervical discectomy and fusion: A biomechanical cadaver study.Clinical biomechanics (Bristol, Avon) · 2026
- Biomechanical comparison of stand-alone interbody bone grafting versus cage implantation in ULIF: a finite element analysisScientific Reports · 2026
- Dual-Plate Allograft Reconstruction for Expansile Lytic Lesions of the Metacarpal May Allow for Immediate Postoperative Weightbearing in a Biomechanical Setting.Hand (New York, N.Y.) · 2026
- Four- and five-level anterior cervical discectomy and fusion with iliac crest autologous bone graft and plate-screw fixation: Radiographic and clinical outcomes with minimum 2-year follow-up.Journal of craniovertebral junction & spine · 2026
- Endo-ACDF with a rigid bendable burr for lesions located at posterior vertebral body: a technical note.British journal of neurosurgery · 2026