A stabilization device significantly improves measurement reliability and efficiency of Graf ultrasonography for developmental dysplasia of the hip: a retrospective cohort study.

Yehui Lan, Liyu Tang, Miao Jin, Bin Du, Jianfei Yan, Quanzhou Wu, Chenying Lu, Yanhua Huang,

Department of Ultrasound, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University, Lishui, Zhejiang, China. · Department of Orthopedics, Lishui Central Hospital, The Fifth Hospital Affiliated to Wenzhou Medical University, Lishui Hospital of Zhejiang University, Lishui, Zhejiang, China.

Observational · n=238

Key points

From the paper's conclusion
  • The use of a stabilization device in Graf hip ultrasonography significantly improves measurement reliability and may enhance examination efficiency and infant comfort without altering diagnostic outcomes, supporting its integration into high-volume DDH screening programs.

Abstract

OBJECTIVES: To compare the measurement reliability, procedural efficiency, and infant stress responses between device-assisted and manual restraint approaches in Graf hip ultrasonography for developmental dysplasia of the hip (DDH) screening. METHODS: In this retrospective cohort study, 238 infants (aged 0-6 months) underwent consecutive hip ultrasound examinations using both a Graf stabilization device and manual restraint during the same visit. Each examination included triple measurements of α and β angles by a single experienced sonographer. Primary outcomes included angle measurements and Graf classification. Examination time and infant crying incidence were also recorded. Intra-observer reliability for repeated measurements within each technique and inter-technique agreement between the two methods were evaluated separately using intraclass correlation coefficients (ICC) and Cohen's kappa. RESULTS: No significant differences were observed in α angle (67.00° vs. 67.50°, P = 0.313), β angle (71.00° vs. 69.00°, P = 0.179), or Graf classification distribution (P = 0.832) between device-assisted and manual methods. However, the device-assisted approach showed significantly shorter examination time (P < 0.001) and a 13.5-fold reduction in crying incidence (0.84% vs. 11.34%, P < 0.001). Intra-observer reliability was excellent with device assistance (α angle: ICC = 0.95, β angle: ICC = 0.90) but poor with manual restraint (α angle: ICC = 0.49, β angle: ICC = 0.23). Inter-technique agreement was moderate for α angle (ICC = 0.71) and substantial for Graf classification (κ = 0.66), but poor with β angle (ICC = 0.36). CONCLUSION: The use of a stabilization device in Graf hip ultrasonography significantly improves measurement reliability and may enhance examination efficiency and infant comfort without altering diagnostic outcomes, supporting its integration into high-volume DDH screening programs.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A stabilization device significantly improves measurement reliability and efficiency of Graf ultrasonography for developmental dysplasia of the hip: a retrospective cohort study — Science Skim