Journal of imaging

AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.

Andrea Audisio, Alessandro Aprato, Jessica Hu, Giorgia Marullo, Matteo Sabbatini, Luca Ulrich, Sandro Moos, Marco Petraz,

Pediatric Orthopaedics and Trauma, Regina Margherita Children's Hospital, 10126 Turin, Italy. · School of Medicine, University of Turin, 10126 Turin, Italy.

Observational

Key points

From the paper's conclusion
  • The workflow supported Checklist I assessment, but fixed order precludes causal CAD inference; gate failures and angle errors require refinement and prospective evaluation before clinical implementation.

Abstract

Graf-method ultrasound supports early assessment of developmental dysplasia of the hip (DDH). This study assessed a sequential artificial-intelligence-assisted workflow and clinicians' Checklist I decisions with and without computer-aided diagnosis (CAD). This retrospective single-centre study of referred infants used 1803 development images from 679 examinations and separate cohorts of 1024 workflow and 100 reader images; Graf IV hips were excluded. ResTransUNet segmented eight Checklist I structures to assess reportability. Fifteen clinicians assessed the reader images unaided and four weeks later with CAD. Stand-alone Checklist I accuracy was 93.0% (93/100; 95% CI 86.3-96.6). Of 1024 workflow images, 846 received final outputs; Checklist II non-compliance precision was 48.1%. Among accepted images, the non-type-I endpoint had 81.0% accuracy, 82.7% sensitivity and 80.4% specificity; exact Graf-type agreement was 40.1%. Across entering non-type-I images, 167/266 (62.8%) received a correct positive output. Mean absolute errors were 3.59° for the α angle and 11.91° for the β angle, with a β-angle bias of +11.07°. Clinician accuracy was 72.3% unaided and 90.2% assisted-an observed 17.9 percentage-point difference (95% CI 10.0-26.1); 26 correct decisions became incorrect on AI-error cases. The workflow supported Checklist I assessment, but fixed order precludes causal CAD inference; gate failures and angle errors require refinement and prospective evaluation before clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort — Science Skim