3D Reconstruction of the Infant Hip Joint from 2D Ultrasound Sweep Sequences for DDH
Jianwei Cui, Wenyi Zhang, Jiakuan Wang, Yuxiang Dai
Key points
From the paper's conclusion- Therefore, this study developed and evaluated a three-dimensional (3D) visualization method for reconstructing infant hip structures from 2D ultrasound sweep sequences.
Abstract
Infant hip ultrasound screening is crucial for the diagnosis of developmental dysplasia of the hip (DDH). However, accurately understanding the complex hip joint anatomy and identifying the Graf standard plane from two-dimensional (2D) ultrasound images alone remains challenging. Therefore, this study developed and evaluated a three-dimensional (3D) visualization method for reconstructing infant hip structures from 2D ultrasound sweep sequences. In this method, a six-degree-of-freedom robotic arm equipped with a 2D linear-array ultrasound probe was used to perform linear scanning of an infant hip ultrasound phantom, synchronously acquiring ultrasound images and the end-effector poses of the robotic arm at 0.2 mm intervals. By fully exploiting information from adjacent frames, BCAS-UNet++, which integrates atrous spatial pyramid pooling and bidirectional convolutional long short-term memory networks, was employed to segment the hip structures. Finally, continuous 3D visualization of the infant hip joint was achieved using an improved MB-Marching Cubes reconstruction algorithm. Experiments based on the phantom dataset yielded an average surface distance of 0.8717 mm, a Hausdorff distance of 2.3713 mm, a Dice coefficient of 0.8536, and an IoU of 0.7446, while the relative errors of the α angle and β angle were 1.04% and 2.83%, respectively. In the preliminary clinical evaluation involving five infants, the mean absolute errors of the α and β angles were 1.14 ± 0.42° and 2.02 ± 0.84°, respectively, with corresponding mean relative errors of 1.70% and 3.23%. Moreover, for the α angle, the 95% limits of agreement ranged from −2.83° to 2.28°, with the systematic bias being close to zero. In conclusion, the proposed method shows promising potential to assist infant DDH screening through 3D visualization and Graf-angle assessment, although further large-scale clinical validation is needed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DDH-Net: A Graf-Compliant Method for Computer-Aided Assessment Using Infant Hip Ultrasound.Bioengineering (Basel, Switzerland) · 2026
- Multihipposenet: multi-task deep learning for automated DDH assessment in infant hip ultrasound.Frontiers in pediatrics · 2026
- The Evaluation of Developmental Dysplasia of Hip from Pediatric Ultrasound Images by Key Point-Based Deep Learning.Diagnostics (Basel, Switzerland) · 2026
- AI-Assisted Sequential Graf Assessment of Infant Hip Ultrasound: A Retrospective Single-Centre Evaluation in a Referral Cohort.Journal of imaging · 2026
- Artificial Intelligence‐Assisted Wireless Handheld Ultrasound for Screening Developmental Dysplasia of the Hip in InfantsJournal of Ultrasound in Medicine · 2026
- VLM-Based Mesh Segmentation Framework for DDH Robotic Ultrasound.Bioengineering (Basel, Switzerland) · 2026