Frontiers in pediatrics

The sound transmission for clinical diagnosis of developmental dysplasia disease of the hip in newborns: a diagnosis study.

Nicolás Padilla-Raygoza, Gilberto Flores-Vargas, María de Jesús Gallardo-Luna, Efraín Navarro-Olivos, Luis Guillermo Patiño-Gutiérrez, Ariana Valeria Girón-Soto, Evaristo Antonio Meza-Galván, Itzel Marcela Anguiano-Canchola,

Department of Research and Technological Development, Directorate of Teaching and Research, Institute of Public Health from Guanajuato State, Guanajuato, México. · Directorate of Teaching and Research, Institute of Public Health from Guanajuato State, Guanajuato, México.

Observational

Key points

From the paper's conclusion
  • Sound transmission using this clinical device complements the evaluation of the hips of newborns.

Abstract

BACKGROUND: Developmental dysplastic hip disease is common in childhood, and clinical maneuvers (e.g., Ortolani and Barlow) detect only subluxation or dislocation. Sound transmission has been proven useful in the diagnosis of this disease. OBJECTIVE: to calculate the validity and repeatability of electromagnetic acoustic wave transmitter-receiver device for the clinical diagnosis of hip dysplasia in newborns. DESIGN: This was a cross-sectional study of newborns at Guanajuato General Hospital whose parents agreed to participate. METHODS: One hundred newborns, between 4 and 27 days of extrauterine life, underwent sound transmission testing with the punctual sound emitter-receiver device placed separately on each hip on three occasions by two examiners. Hip ultrasound was performed using the Graf technique as the gold standard. Validity (sensitivity, specificity, and predictive values) and Cohen's Kappa were calculated to determine the reliability of the device. RESULTS: Of the 200 hips, 15 right and 18 left hips were diagnosed with dysplasia using the Graf technique ultrasound; a validity greater than 90% was obtained in the three measurements. Repeatability with intra-observer Kappa values were 0.76 for the right hip and 0.82 for the left hip, while inter-observer Kappa values were 0.90 for the right hip and 0.81 for the left hip. CONCLUSION: Sound transmission using this clinical device complements the evaluation of the hips of newborns.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

The sound transmission for clinical diagnosis of developmental dysplasia disease of the hip in newborns: a diagnosis study — Science Skim