A deep learning approach for EPID-based patient-specific quality assurance incorporating daily machine-state variations.
Kihong Pak, Sung-Woo Kim, Kyeongyun Park, Byungchul Cho, Yeon Joo Kim, Si Yeol Song, Chiyoung Jeong, Jungwon Kwak
Department of Radiation Oncology, Asan Medical Center, Seoul, Republic of Korea. · Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Key points
From the paper's conclusion- These findings suggest the potential value of a fraction-level, machine-state-aware PSQA, in which the pretreatment measurement establishes a baseline and subsequent daily MPC data are used to update the expected GPR of the approved plan on the day each fraction is delivered.
Abstract
Patient-specific quality assurance (PSQA) based on electronic portal imaging devices (EPIDs) is widely used for pretreatment verification, but it is usually performed as a single check of the approved plan and reflects the daily state of the linac only to a limited extent. We propose a deep learning approach that predicts the measured EPID image from the calculated portal dose image using the daily machine state as a conditioning input. A Pix2Pix conditional generative adversarial network was trained to translate Anisotropic Analytical Algorithm portal dose images into measured EPID images, with a 235-dimensional Machine Performance Check (MPC) feature vector added as a conditioning input. Synthetic multi-leaf collimator deviation samples were also introduced during training to represent positioning offsets. Six model variants were evaluated across multiple anatomical sites, combining two prediction targets (the EPID image or the dose-difference map) with three input configurations (baseline, MPC, and MPC with deviation augmentation). Gamma analysis was performed at 3%/3 mm, 3%/2 mm, and 2%/2 mm. The difference-target model with full MPC integration performed best, reaching a root-mean-square error of 0.48 percentage points (pp) and a Pearson correlation of 0.944 for the gamma passing rate (GPR) at 3%/2 mm. On perturbed plans, adding MPC features together with deviation-aware augmentation reduced the absolute GPR prediction error by 42%. Incorporating measured machine-state information improved EPID-based PSQA prediction under the MLC perturbations evaluated in this study. These findings suggest the potential value of a fraction-level, machine-state-aware PSQA, in which the pretreatment measurement establishes a baseline and subsequent daily MPC data are used to update the expected GPR of the approved plan on the day each fraction is delivered. Further prospective evaluation of clinically relevant error detection and false-negative risk is warranted. Nevertheless, this approach may provide a basis for extending PSQA from a single pretreatment assessment toward fraction-level monitoring of patient-specific delivery quality during the treatment course.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- BeamGAN: a physics-informed conditional generative adversarial network for Monte-Carlo-free portal dose image prediction from incident fluence maps.Physics in medicine and biology · 2026
- Deep learning for gamma map prediction in breast IMRT verificationMedical Physics · 2026
- Machine learning prediction of electronic-portal-imaging-device-based in vivo dosimetry results using plan complexity metrics, machine output and gamma passing rate: a feasibility study.Physical and engineering sciences in medicine · 2026
- Evaluation of a multifunctional phantom for geometric, image quality, and dosimetric constancy of megavoltage electronic portal imaging devicesJournal of Applied Clinical Medical Physics · 2026
- Sensitivity in error detection of an electronic portal imaging device for patient-specific QA in head and neck VMAT plans.Radiological physics and technology · 2026
- Daily Multi-Leaf Collimator positional error prediction using machine learning: A Dynalog-based approach for patient specific quality assurance.Journal of applied clinical medical physics · 2026