BeamGAN: a physics-informed conditional generative adversarial network for Monte-Carlo-free portal dose image prediction from incident fluence maps.

Tianlong Ji, Wenjun Tan, Dazhe Zhao

School of Computer Science and Engineering, Northeastern University, Wenhua Road, Shenyang, 110819, Liaoning, China, Shenyang, Liaoning, 110819, China. · Northeastern University, No.11, Lane 3, Culture Road, Heping District, Shenyang, Liaoning Province, China, Shenyang, Liaoning, 110819, China.

Computational · n=12

Key points

From the paper's conclusion
  • We propose BeamGAN, a physics-informed conditional generative adversarial network.

Abstract

To develop and validate a Monte-Carlo-free deep learning framework that predicts EPID portal dose images directly from treatment-planning-system (TPS) exported incident fluence maps, enabling real-time patient-specific quality assurance (QA) without Monte Carlo (MC) simulation or empirical per-machine commissioning. Approach. We propose BeamGAN, a physics-informed conditional generative adversarial network. A three-channel input-TPS incident fluence, its Sobel gradient map, and a beam's-eye-view (BEV) target-thickness projection ray-traced through the planning CT with the PTV mask-embeds geometric and edge-scatter priors into an eight-level U-Net generator with a PatchGAN discriminator and an auxiliary registration network. The framework was trained on 91 head-and-neck IMRT patients (split 64/15/12) from one Elekta Versa HD linac, benchmarked against a Brownian-Bridge diffusion baseline (BiBBDM), and evaluated by input-channel ablation and error-injection sensitivity tests. Main results. BeamGAN achieved gamma passing rates (GPR) of 97.40 ± 0.67% (3%/3 mm), 95.42 ± 0.99% (3%/2 mm) and 87.00 ± 1.63% (2%/2 mm; 10% threshold), outperforming BiBBDM (83.32 ± 2.43%, 77.08 ± 3.20% and 67.20 ± 2.45%). On the held-out test set (n = 12), the median GPR was 95.47% (IQR 94.86-96.27) at the TG-218 primary criterion 3%/2 mm; 8/12 cases met the institutional ≥95% acceptance threshold and all 12 exceeded the 90% action level. Ablation identified the fluence-gradient channel as the dominant contributor, with the anatomical prior providing complementary gains. Sensitivity analysis established a criterion-dependent error hierarchy: systematic MLC errors were most detectable (ΔGPR up to 21.23% at 1%/1 mm), followed by collimator rotation (10.31%), whereas MU scaling and setup errors produced marginal effects. BEV computation required 0.3-0.5 s per beam and inference under 50 ms. Significance. Embedded geometric priors can approximate explicit MC scatter modelling in portal dose prediction, removing a principal computational barrier to real-time EPID-based verification within the validated configuraiton. Multi-institutional validation is warranted before clinical deployment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers