Risk-based redesign of internal quality control procedures for emergency immunoassays in clinical laboratories: a multicenter study from China.
Guangjun Xiao, Juan Hu, Yanting Liu, Sihan Zhao, Weifeng Liao, Huanhuan Wang, Shaocheng Zhang
Department of Clinical Laboratory, Suining Central Hospital, Suining, Sichuan, China. · School of Laboratory Medicine, Chengdu Medical College, Chengdu, Sichuan, China.
Key points
From the paper's conclusion- Baseline IQC practices for emergency immunoassays in the surveyed laboratories were inconsistent and lacked a standardized risk-based foundation. We recommend that clinical laboratories implement individualized RB-SQC protocols designed using the Westgard Sigma Rule with Run Length nomogram, and periodically reassess their appropriateness based on updated sigma metrics.
Abstract
BACKGROUND: Although clinical laboratories routinely implement internal quality control (IQC) to ensure the reliability of test results, emergency immunoassay testing introduces unique operational challenges. To mitigate financial burdens, some laboratories arbitrarily extend IQC batch lengths or reduce the number of quality control (QC) samples per analytical run. This study evaluated baseline IQC practices for emergency immunoassays across five laboratories in Suining, China, aiming to provide evidence-based guidance for regional quality improvement. METHODS: Average daily test volumes, external quality assessment (EQA) results, and historical IQC data were retrospectively collected from the five laboratories. Sigma metrics were calculated for each analyte. Concurrently, the "Westgard Sigma Rule with Run Length" nomogram was applied to design individualized, risk-based statistical quality control (RB-SQC) procedures. RESULTS: All emergency immunoassays, except for serum procalcitonin, were subjected to routine IQC across all five laboratories; notably, certain analytes followed an extended 72-h IQC batch interval. Within individual laboratories, QC rules, the number of QC results per batch, and batch lengths were consistent across analytes but varied between laboratories. Under the current QC scheme, the QC utilization rate (N/M-1) was 0.087 (0.047-0.143), which decreased significantly to 0.020 (0.004-0.133) after implementing RB-SQC procedures (N/M-2; Z = 3.154, P < 0.05), suggesting that RB-SQC may reduce QC material and reagent consumption while maintaining acceptable patient risk. However, arbitrary adjustments to batch lengths or the number of QC results may lead to elevated or reduced QC utilization rates. CONCLUSIONS: Baseline IQC practices for emergency immunoassays in the surveyed laboratories were inconsistent and lacked a standardized risk-based foundation. We recommend that clinical laboratories implement individualized RB-SQC protocols designed using the Westgard Sigma Rule with Run Length nomogram, and periodically reassess their appropriateness based on updated sigma metrics.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A longitudinal EQA-based process sigma framework for risk-oriented quality management of infectious disease immunoassays.Diagnostic microbiology and infectious disease · 2026
- A-307 Determining risk-based internal quality control frequency for biochemical testing using Sigma metrics and the QC Constellation toolClinical Chemistry · 2026
- Internal quality control for immunodiagnostic laboratories.Asian journal of transfusion science · 2026
- B-275 Operational and Environmental Benefits of Load-and-Go Liquid QC in Clinical ChemistryClinical Chemistry · 2026
- Evaluation and application of automated quality control in clinical coagulation testing.Research and practice in thrombosis and haemostasis · 2026
- Application of Six Sigma, Quality Goal Index, Method Decision Chart, and Operating Specification Metrics as Stringent Quality Control Tools for Assessing the Analytical Performance of BUN, Creatinine, and Glucose in an ISO 15189:2022–Accredited LaboratoryThe Journal of Applied Laboratory Medicine · 2026