A-307 Determining risk-based internal quality control frequency for biochemical testing using Sigma metrics and the QC Constellation tool
Suong Nguyen
Key points
From the paper's conclusion- Conclusion The combined application of Sigma metrics and the QC Constellation tool provides an effective method for determining risk-based IQC frequency in biochemical testing.
Abstract
Background Risk-based internal quality control (IQC) has been increasingly adopted in clinical laboratories to enhance analytical quality and patient safety. ISO 15189:2022 recommends designing IQC plans based on risk assessment rather than applying fixed QC frequencies. Sigma metrics combined with the QC Constellation tool provide an objective approach to optimize IQC strategies. Methods A retrospective analysis of IQC and external quality assessment data was performed from October 2023 to September 2024 for six routine biochemical tests, including albumin, total bilirubin, cholesterol, triglyceride, gamma-glutamyl transferase, and lipase, analyzed on the AU5800 biochemical analyzer at the University Medical Center Ho Chi Minh City. Sigma metrics were calculated using total allowable error, bias, and imprecision. The QC Constellation tool was applied to determine the optimal run size corresponding to a MaxE(Nuf) risk level of less than 1. Results Cholesterol demonstrated a Sigma performance of approximately 3, whereas the remaining analytes achieved Sigma metrics greater than 5. Based on these performance levels, the QC Constellation tool proposed optimized run sizes that allowed adjustment of IQC frequency according to analytical risk. The optimized QC plan reduced unnecessary QC events while maintaining acceptable error detection capability. Conclusion The combined application of Sigma metrics and the QC Constellation tool provides an effective method for determining risk-based IQC frequency in biochemical testing. This approach minimizes the risk of undetected analytical errors, reduces QC-related costs, and supports compliance with ISO 15189:2022 requirements.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Application of Six Sigma, Quality Goal Index, Method Decision Chart, and Operating Specification Metrics as Stringent Quality Control Tools for Assessing the Analytical Performance of BUN, Creatinine, and Glucose in an ISO 15189:2022–Accredited LaboratoryThe Journal of Applied Laboratory Medicine · 2026
- B-265 A Large Multisite Study of Beckman Coulter clinical chemistry performance demonstrates a significant majority of assays are eligible to use less QCClinical Chemistry · 2026
- Longitudinal Sigma-Metric Profiling of Two Clinical Chemistry Platforms Using Peer-Group Internal Quality Control.Diagnostics (Basel, Switzerland) · 2026
- B-266 A multisite review across the USA of major competitive biochemistry platforms reveals significant differences in analytical performanceClinical Chemistry · 2026
- Risk-based redesign of internal quality control procedures for emergency immunoassays in clinical laboratories: a multicenter study from China.Frontiers in medicine · 2026
- Sigma metric and Quality Goal Index assessment of hemoglobin A1c analytical performance in an ambulatory accredited laboratory.Laboratory medicine · 2026