Effect of polydopamine on bonding characteristics and color stability of blood contaminated Biodentine to composite.
Ihtisam Alam, Aravind R Kudva, S Vidhyadhara Shetty, Jayprakash Kukkila
Department of Conservative Dentistry and Endodontics, Yenepoya Dental College,Yenepoya (Deemed to be University), Mangaluru, Karnataka, India. · Department of Dental Materials, Biomaterials and Research Center, Yenepoya (Deemed to be University) Dental College, Mangaluru, Karnataka, India.
Key points
From the paper's conclusion- Within the limitations of this in vitro study, blood contamination occurring during setting reduced the shear bond strength of Biodentine to resin composite and increased its discolouration. PDA pretreatment significantly improved bond strength in contaminated specimens only, abolishing the statistically significant contamination penalty, and did so without aggravating colour change.
Abstract
INTRODUCTION: Calcium silicate cements such as Biodentine are frequently placed in a blood-contaminated field during vital pulp therapy and must subsequently be bonded to an overlying resin composite. Polydopamine (PDA) improves the wettability and bond strength of mineral trioxide aggregate to resin composite, but its effect on blood-contaminated Biodentine is unknown. AIM: To determine the effect of PDA pretreatment on the shear bond strength (SBS), failure mode and colour change (ΔE) of blood-contaminated and uncontaminated Biodentine bonded to resin composite. MATERIALS AND METHODS: Seventy-six standardised Biodentine specimens (5 mm diameter × 3 mm) were prepared with blood contamination (present/absent) and PDA pretreatment (present/absent) as the two factors (n = 19 per cell). After adhesive application, bulk-fill composite build-up and 45 days of storage at 37 °C, SBS was measured, failure modes and ΔE was analysed. RESULTS: Blood contamination significantly reduced SBS [F(1,72) = 18.86, P < 0.001, partial η 2 = 0.21] and the contamination × PDA interaction was significant [F(1,72) = 7.39, P = 0.008, partial η 2 = 0.09], whereas the main effect of PDA was not [F(1,72) = 2.07, P = 0.155]. Simple-effect analysis showed that PDA increased SBS in contaminated specimens (6.44 → 7.77 MPa; mean difference 1.33 MPa, 95% CI 0.43-2.23; P = 0.004) but not in uncontaminated specimens (8.70 → 8.29 MPa; P = 0.368). Without PDA, contamination lowered SBS by 2.26 MPa (P < 0.001), whereas after PDA pretreatment the difference between contaminated and uncontaminated specimens was no longer significant (P = 0.254). Contamination significantly increased ΔE (P < 0.001) whereas PDA did not (P = 0.102); all groups exceeded the clinical acceptability threshold. Failure-mode distribution differed significantly among groups (Fisher-Freeman-Halton exact P = 0.021; Cramér's V = 0.30), cohesive failure within Biodentine predominating in the contaminated groups. CONCLUSIONS: Within the limitations of this in vitro study, blood contamination occurring during setting reduced the shear bond strength of Biodentine to resin composite and increased its discolouration. PDA pretreatment significantly improved bond strength in contaminated specimens only, abolishing the statistically significant contamination penalty, and did so without aggravating colour change.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Catechol-based polydopamine modification of a dentin adhesive: effects on surface wettability, microhardness recovery, and mineral deposition.Journal of materials science. Materials in medicine · 2026
- Bonding Performance of a Universal Adhesive to Blood‐ and Blood–Saliva‐Contaminated Mineral Trioxide Aggregate: Effect of Cleaning MethodsClinical and Experimental Dental Research · 2026
- Comparison of Tooth Discoloration Induced by Mineral Trioxide Aggregate and Polycarboxylate Cement Containing Potassium Nitrate in the Presence and Absence of Blood: An Ex Vivo Study.International journal of dentistry · 2026
- MDP-based Cleaner Restores the Bond Strength and Chemical Interaction of a Self-adhesive Resin Cement to Blood-contaminated Zirconia.The journal of adhesive dentistry · 2026
- Adhesion of Bioactive Glass Nanoparticle-Modified Biodentine Under Simulated Early and Aged Conditions.European endodontic journal · 2026
- Effect of a self-assembling peptide (P11-4) and dentin matrix protein 1 (DMP-1) on the bond strength of resin composites to caries-affected dentin.Journal of dentistry · 2026