Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V.
Jiantao Deng, Xiaoping Fan, Qingwei Zhang, Jing Yan, Yong Li, Gaowu Yan, Linwei Zhao, Xiaocheng Shen,
Department of Radiology, Suining Central Hospital, Suining, China. · Department of Radiology and Imaging, Institute of Rehabilitation and Development of Brain Function, The Second Clinical Medical College of North Sichuan Medical College Nanchong Central Hospital, Nanchong, China.
Key points
From the paper's conclusion- Objective To investigate the effects of a dual-energy CT (DECT) protocol combining virtual monoenergetic imaging (VMI) with adaptive statistical iterative reconstruction-V (ASIR-V) on image quality and radiation dose for inferior vena cava (IVC) CT angiography (CTA), and to compare the optimized protocol with a conventional 120 kVp protocol.
Abstract
OBJECTIVE: To investigate the effects of a dual-energy CT (DECT) protocol combining virtual monoenergetic imaging (VMI) with adaptive statistical iterative reconstruction-V (ASIR-V) on image quality and radiation dose for inferior vena cava (IVC) CT angiography (CTA), and to compare the optimized protocol with a conventional 120 kVp protocol. METHODS: 120 consecutive patients undergoing IVC-CTA were enrolled and allocated sequentially to two groups (n = 60 each). Group A underwent conventional 120 kVp scanning with 400 mgI/mL contrast medium at 1.5 mL/kg and 50% ASIR-V reconstruction. Group B underwent DECT (rapid 80/140 kVp switching) with 320 mgI/mL contrast medium at 1.2 mL/kg. In Group B, seven VMI datasets from 40 to 70 keV in 5 keV increments were first reconstructed with 50% ASIR-V. At 60 keV, images were reconstructed with filtered back projection (FBP; 0% ASIR-V) and ASIR-V levels from 20% to 100% in 20% increments. Objective image quality was assessed using CT attenuation, standard deviation (SD), background noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at five venous levels. Two radiologists independently rated subjective image quality and diagnostic confidence on 5-point Likert scales. Dose-length product (DLP), effective dose (ED), contrast medium volume, and iodine intake were also recorded and compared between protocols. RESULTS: In Group B, with ASIR-V fixed at 50%, CT attenuation, SD, background noise, SNR, and CNR decreased progressively as VMI energy increased. Among the seven VMI levels, 60 keV achieved the highest subjective image-quality score (all P < 0.05). At 60 keV, increasing ASIR-V reduced vascular SD and background noise and increased SNR and CNR. The 60 keV VMI plus 60% ASIR-V combination (Group B1) achieved the highest subjective score. Compared with Group A, Group B1 had significantly higher IVC CT attenuation and background noise (both P < 0.001), but SNR, CNR, and subjective image-quality scores did not differ significantly (all P > 0.05). Diagnostic-confidence scores for thrombosis, luminal stenosis, post-filter placement, and normal IVC findings were similar between Groups A and B1 (all P > 0.05). Relative to Group A, Group B1 reduced contrast medium volume, iodine intake, and ED by approximately 20.0%, 36.0%, and 12.51%, respectively (all P < 0.001). CONCLUSION: The DECT protocol combining 60 keV VMI with 60% ASIR-V provided a favorable balance of image quality for IVC-CTA. The optimized protocol achieved SNR, CNR, subjective image quality, and diagnostic confidence similar to those of the conventional 120 kVp protocol while reducing contrast medium volume, iodine intake, and effective radiation dose.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- Dual-energy computed tomography pulmonary angiography for pulmonary embolism: a three-tier evidence framework to guide individualized low-iodine scanning.Diagnostic and interventional radiology (Ankara, Turkey) · 2026
- Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.Radiologie (Heidelberg, Germany) · 2026
- Image quality assessment of 40-keV virtual monoenergetic reconstruction in low-contrast lower-extremity spectral CT angiography.Radiography (London, England : 1995) · 2026
- Study on the combined application of selected virtual monoenergetic imaging, virtual non-contrast imaging, and adaptive statistical iterative reconstruction-V in head and neck CT angiography using 256-slice wide-body CT.Frontiers in medicine · 2026
- Personalized low-iodine dual-layer spectral CT protocol for post-endovascular aortic repair imaging: a BMI/eGFR-adapted strategy preserving renal function, quality and diagnostic confidence.Clinical radiology · 2026