Image quality assessment of 40-keV virtual monoenergetic reconstruction in low-contrast lower-extremity spectral CT angiography.
A M Augustin, M E Sosa Contreras, A Grandel, T Klink
Institute of Radiology, Neuroradiology and Interventional Therapy, Klinikum Bayreuth GmbH, Medical Campus Upper Franconia, Friedrich-Alexander University Erlangen-Nürnberg, Preuschwitzer Straße 101, 95445 Bayreuth, Germany; Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany. Electronic address: annemarie.augustin@klinikum-bayreuth.de. · Institute of Radiology, Neuroradiology and Interventional Therapy, Klinikum Bayreuth GmbH, Medical Campus Upper Franconia, Friedrich-Alexander University Erlangen-Nürnberg, Preuschwitzer Straße 101, 95445 Bayreuth, Germany.
Key points
From the paper's conclusion- Forty-keV virtual monoenergetic reconstruction significantly improves quantitative and qualitative image-quality parameters in low-contrast lower-extremity spectral CTA compared with conventional reconstructions. These findings suggest that low-keV VMI may improve image-quality characteristics in reduced-contrast CTA protocols, particularly in distal arterial segments.
Abstract
INTRODUCTION: Lower-extremity CT angiography (CTA) is widely used for the assessment of peripheral arterial disease. Reducing iodinated contrast medium is desirable, particularly in patients with impaired renal function. This study evaluated the impact of 40-keV virtual monoenergetic images (VMI) on image quality in low-contrast lower-extremity spectral CTA. METHODS: In this retrospective single-center study, 60 patients who underwent lower-extremity spectral CTA with 40 mL of iodinated contrast medium were included. Conventional reconstructions and 40-keV VMI were compared regarding vascular attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine concentration, and subjective image quality across predefined arterial segments. Qualitative image quality was independently assessed by two readers using a 5-point Likert scale. RESULTS: Compared with conventional reconstructions, 40-keV VMI significantly increased vascular attenuation, SNR, and CNR across all arterial segments (all p < 0.001). Subjective ratings for vessel contrast, vessel sharpness, overall image quality, and diagnostic confidence were significantly higher with VMI for both readers across all evaluated arterial segments (all p < 0.05). Iodine concentration decreased progressively from proximal to distal arterial segments, whereas the CNR advantage of VMI remained preserved throughout the arterial tree. CONCLUSION: Forty-keV virtual monoenergetic reconstruction significantly improves quantitative and qualitative image-quality parameters in low-contrast lower-extremity spectral CTA compared with conventional reconstructions. These findings suggest that low-keV VMI may improve image-quality characteristics in reduced-contrast CTA protocols, particularly in distal arterial segments. IMPLICATIONS FOR PRACTICE: Low-keV virtual monoenergetic reconstruction may support reduced-contrast lower-extremity CTA protocols by improving image quality without increasing contrast medium volume. This approach may be particularly valuable for patients in whom minimizing iodinated contrast medium exposure is desirable.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Study on the combined application of selected virtual monoenergetic imaging, virtual non-contrast imaging, and adaptive statistical iterative reconstruction-V in head and neck CT angiography using 256-slice wide-body CT.Frontiers in medicine · 2026
- Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V.Frontiers in cardiovascular medicine · 2026
- Personalized low-iodine dual-layer spectral CT protocol for post-endovascular aortic repair imaging: a BMI/eGFR-adapted strategy preserving renal function, quality and diagnostic confidence.Clinical radiology · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026
- Feasibility of low concentration iodinated contrast medium in portal venous abdominal imaging: performance of photon-counting CT virtual monoenergetic imaging compared to conventional EID-CT.European journal of radiology · 2026
- Plaque-Adapted Virtual Monoenergetic Image Selection for Carotid Plaque Visualization Using Photon-Counting CT.Diagnostics (Basel, Switzerland) · 2026