Feasibility of reducing radiation dose and contrast dose while improving image quality in dual-energy CT pulmonary angiography : Use of low-energy virtual monochromatic images with deep learning image reconstruction algorithm.
Zhanli Ren, Tianli Wang, Li Shen, Min Zhang, Dong Han, Nan Yu, Zhanliang Ren
Affiliated Hospital of Shaanxi University of Chinese Medicine, Weiyang western road-2#, 712000, Xianyang, Shaanxi, China. · Shaanxi Fashion Engineering University, No.1 of Tongwen Road, Fengxi New City of Xixian New Area, 712046, Xi'an, Shaanxi, China.
Key points
From the paper's conclusion- Combining DLIR‑H with VMIs, especially 40 keV, in DECTPA leads to reduced contrast and radiation doses while improving image quality.
Abstract
BACKGROUND: We explored the feasibility of reducing both radiation and contrast doses while improving image quality using low-energy virtual monochromatic images (VMIs) in dual-energy computed tomography (CT) pulmonary angiography (DECTPA) with deep learning image reconstruction at a high setting (DLIR-H). MATERIALS AND METHODS: A total of 60 patients scheduled for CTPA were randomly divided into two groups: group A (n = 30) with 120 kV, contrast dose of 0.8 mL/kg, and adaptive statistical iterative reconstruction‑V (ASIR-V) at a 60% strength level, and group B (n = 30) with dual-energy CT (DECT), contrast dose of 0.6 mL/kg, and DLIR‑H at 40 keV, 50 keV, 60 keV and 70 keV VMIs. The CT and standard deviation (SD) values of the pulmonary arteries were measured to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Image quality was subjectively scored blindly by two radiologists using a five-point scale. RESULTS: There were no differences in general patient demographics between the two groups (all p > 0.05). In group B, the contrast and radiation doses decreased by 29.6% and 53.1%, respectively, compared to group A (p < 0.05). Compared to group A, group B had significantly higher CT and SNR values for the 40 keV-60 keV VMIs and higher CNR for the 40 keV-70 keV VMIs (all p < 0.05), with similar image noise at 60 keV. The two radiologists had substantial agreement in subjective scoring (kappa > 0.80). There were significantly higher scores for the 40 keV-60 keV VMIs in group B compared to group A (all p < 0.05), with the 40 keV VMIs having the highest scores. CONCLUSION: Combining DLIR‑H with VMIs, especially 40 keV, in DECTPA leads to reduced contrast and radiation doses while improving image quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Deep learning reconstruction combined with contrast enhancement boost improves image quality of low-contrast-dose ctpa: a prospective randomized study.BMC medical imaging · 2026
- Deep learning image reconstruction for 50-keV virtual monoenergetic dual-energy CT of the thyroid: a prospective "dual-low" dose study.European radiology · 2026
- Quantitative and task‐based performance of spectral deep learning reconstruction in low‐dose dual‐layer coronary CT angiography: A phantom studyMedical Physics · 2026
- Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V.Frontiers in cardiovascular medicine · 2026
- Improved virtual non-contrast images in liver dual-energy CT with deep learning algorithm for image reconstruction.Radiologie (Heidelberg, Germany) · 2026
- Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.Diagnostics (Basel, Switzerland) · 2026