Key points
From the paper's conclusion- This case highlights the importance of diagnostic role of electrocardiography to detect lead dislodgement. In patents with surgically altered right atrium, individualized pacing strategies, such as single-chamber ventricular pacing, may be appropriate. Novel atrial pacing lead with fix helix or leadless pacing might do some help to reduce the risk of dislodgement.
Abstract
BACKGROUND: Atrial lead dislodgment is not uncommon after permanent pacemaker implantation, especially in patients with atrial anatomic abnormity. Unique electrocardiography manifestation might give clues for promptly diagnosis. In patients with reconstructed right atrium, optimal pacing strategies and lead stability remain challenging. CASE PRESENTATION: A 44-year-old woman developed symptomatic sinus node dysfunction after right atrial tumor resection and reconstruction. A dual-chamber pacemaker was implanted, resulting in symptom resolution. At routine follow-up, electrocardiography showed ventricle was intermittently captured by one initial pacing artifact which was immediately followed by another pacing artifact at a fixed interval of 110-ms, consistent with ventricular safety pacing. Device interrogation revealed normal ventricular lead parameters but loss of atrial capture. Imaging confirmed atrial lead dislodgement into the right ventricle. The atrial lead was subsequently extracted and the device was reprogrammed to VVI mode. After 3 months follow-up, the patient remained asymptomatic and was with normal cardiac function. CONCLUSION: This case highlights the importance of diagnostic role of electrocardiography to detect lead dislodgement. In patents with surgically altered right atrium, individualized pacing strategies, such as single-chamber ventricular pacing, may be appropriate. Novel atrial pacing lead with fix helix or leadless pacing might do some help to reduce the risk of dislodgement.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Early Right Ventricular Implantable Cardioverter-Defibrillator Lead Microdislodgement Associated With Active-Fixation Helix Retraction: A Case Report.Cureus · 2026
- Delayed Right Atrial Lead Perforation: Discrepancy Between Preoperative Findings and Surgical Inspection.Pacing and clinical electrophysiology : PACE · 2026
- Atrial Leadless Pacemaker Implantation at the Superior Right Atrial Site.Heart rhythm · 2026
- A Perforation Mimic After Temporary Pacing Lead Migration: Surgical Confirmation of Marked Apical Wall Thinning.JACC. Case reports · 2026
- Inadvertent Left Ventricular Pacing Through an Unrecognized Sinus Venosus Atrial Septal Defect.JACC. Case reports · 2026
- Rethinking atrial pacing support in cardiac resynchronization therapy: insights from the CRT-NEXT trial.Heart failure reviews · 2026