Rethinking atrial pacing support in cardiac resynchronization therapy: insights from the CRT-NEXT trial.
Arman Soltani Moghadam, Saman Soltani Moghadam, Mandana Ebrahimzade, Yasaman Daryabari, Aida Zeinali, Toshiki Kuno, Kaveh Hosseini
Cardiovascular Diseases Research Institute, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran. · Cardiology Division, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Key points
From the paper's conclusion- These findings challenge the routine need for atrial pacing support in carefully selected CRT-D candidates and suggest that reliable atrial sensing may be sufficient for most patients without sinus node dysfunction.
Abstract
Cardiac resynchronization therapy defibrillators traditionally require a dedicated right atrial lead to provide atrial sensing and pacing in addition to biventricular pacing. However, the clinical value of routine atrial pacing in CRT recipients without sinus node dysfunction remains uncertain, while additional transvenous leads increase procedural complexity and lead-related complications. The CRT-NEXT trial evaluated whether a simplified two-lead CRT-DX system, capable of atrial sensing through a floating atrial dipole but without atrial pacing, was non-inferior to conventional three-lead CRT-D. In this randomized non-inferiority trial, CRT-DX met the prespecified non-inferiority criterion for the composite endpoint of all-cause mortality, cardiovascular hospitalization, and lead-related complications at 12 months. Mortality, cardiovascular hospitalization, arrhythmic outcomes, reverse remodeling, and functional capacity were comparable between groups, while CRT-DX was associated with shorter procedure time and fewer atrial lead-related complications. Importantly, atrial sensing remained reliable during follow-up, CRT delivery was preserved, and only one patient required late atrial lead implantation. These findings challenge the routine need for atrial pacing support in carefully selected CRT-D candidates and suggest that reliable atrial sensing may be sufficient for most patients without sinus node dysfunction. Future integration of DX-based atrial sensing with conduction system pacing may further advance device simplification toward single-lead CRT-D platforms.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Role of Atrial Pacing Support in Cardiac Resynchronization Therapy: A Noninferiority Randomized TrialCirculation · 2026
- Atrial Pacing Capability of a Single-Lead Implantable Cardioverter-Defibrillator Incorporating an Atrial Floating Dipole.Journal of cardiovascular electrophysiology · 2026
- Efficacy of Atrioventricular Node Ablation Versus Medical Rate Control for Enhancing CRT Response in Permanent Atrial Fibrillation: A Systematic Review and Meta-Analysis of Randomized Controlled TrialsCardiology in Review · 2026
- Cardiac implantable electronic devices in heart failure: needs, challenges, and real-world implementation.Heart failure reviews · 2026
- First-in-Human Permanent Totally Leadless Left Ventricular Septal Endocardial Pacing With Atrioventricular Synchrony.JACC. Case reports · 2026
- One Catheter, Two Chambers: Feasibility and Acute Procedural Outcomes of Dual-Chamber Leadless Pacemaker Implantation with a Single Delivery Catheter.Journal of clinical medicine · 2026