Mind the gap: discrepancies between planned and achieved screw trajectories in 3D-navigated spine surgery.
Ulf Bertram, Laure Weis, Tobias P Schmidt, Alexander Romagna, Miguel Pishnamaz, Hans Clusmann, Christian Blume, Christian-Andreas Mueller
1Department of Neurosurgery, RWTH Aachen University, Medical Center, Aachen. · 2Department of Neurosurgery, Muenchen Klinik Bogenhausen, Munich, Germany.
Key points
From the paper's conclusion- Screw trajectory deviations vary by spinal region, with the greatest axial discrepancies observed in the subaxial cervical spine. These findings highlight the importance of recognizing intraoperative navigation limitations and refining surgical techniques to optimize accuracy. Monitoring screw trajectories may enhance training and improve patient safety.
Abstract
OBJECTIVE: Intraoperative 3D image-guided navigation has improved the accuracy of posterior screw placement in spine surgery. However, discrepancies between planned and achieved screw trajectories remain underexplored. In this study, authors assessed these deviations across spinal regions and their potential correlation with screw misplacement. METHODS: They prospectively analyzed patients undergoing posterior instrumented fusion surgery between 2021 and 2023. Screw placement accuracy was graded using the 2-mm increment basis of the Gertzbein and Robbins (GR) classification. Additionally, angulation discrepancies between planned and achieved trajectories were measured in the axial and sagittal planes. Statistical analyses included Kruskal-Wallis, Dunn's post hoc, and Spearman correlation tests. RESULTS: The study included 725 pedicle and lateral mass screw trajectories in 121 patients. Overall, 95.0% of screws were placed with acceptable accuracy (cervical spine: GR grade A and B; all other spine regions: GR grade A-C). Axial screw trajectory divergence was highest in the subaxial cervical spine (4.2° ± 3.0°), significantly exceeding those in the atlantoaxial (2.6° ± 2.1°), thoracic (2.6° ± 2.2°), and lumbar (2.9° ± 3.2°) regions (p < 0.01). Sagittal divergence was greater in the subaxial cervical spine (4.1° ± 4.0°) than in the thoracic spine (2.8° ± 2.7°; p < 0.001). The correlation between trajectory deviations and screw misplacement was weak or absent. CONCLUSIONS: Screw trajectory deviations vary by spinal region, with the greatest axial discrepancies observed in the subaxial cervical spine. These findings highlight the importance of recognizing intraoperative navigation limitations and refining surgical techniques to optimize accuracy. Monitoring screw trajectories may enhance training and improve patient safety.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative study of pedicle screw trajectory in scoliosis surgery: freehand technique versus navigated angular guidance using the PYTHEAS Your Guided Trajectory.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Accuracy of robot-assisted cortical bone trajectory pedicle screw placement: CT-based retrospective cohort study.Acta orthopaedica Belgica · 2026
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- Intraoperative Trajectory Realignment Algorithm for Minimizing Screw Misplacement in Cervical Spinal Fusion.Computational and structural biotechnology journal · 2026
- Accuracy of 3D-navigated screw fixation in pelvic ring fractures: a single-centre consecutive observational case seriesEuropean Journal of Orthopaedic Surgery & Traumatology · 2025