Comparative study of pedicle screw trajectory in scoliosis surgery: freehand technique versus navigated angular guidance using the PYTHEAS Your Guided Trajectory.
David Afonso, Kenny Rozenfeld, Estelle Litzelmann, Sébastien Pesenti, Hadrien Giorgi, Aymeric Faure, Yann Glard
Hôpital Saint Joseph, Marseille, France. d.afonso@hotmail.fr. · Hôpital Saint Joseph, Marseille, France.
Key points
From the paper's conclusion- The PYGT system significantly improved radiographic pedicle screw placement accuracy in posterior spinal surgery and reduced directional errors compared with the freehand technique, particularly in deformity surgery. These findings support the technical effectiveness of the system. Further studies are required to determine whether these improvements translate into clinically meaningful benefits. Direct comparative studies with contemporary navigation and robotic systems are also needed to better define the role of PYGT with regard to radiation exposure, operative time, workflow, cost-effectiveness, and clinical outcomes.
Abstract
INTRODUCTION: Pedicle screw fixation is the reference technique in scoliosis surgery, enabling optimal three-dimensional correction and solid spinal stabilization. However, the risk of screw malposition remains significant, particularly in severe deformities, due to vertebral rotation and pedicle dysplasia. Technological advances such as intraoperative navigation and robotic assistance have consistently been shown to improve pedicle screw placement accuracy but are limited by cost, complex workflow, and intraoperative radiation exposure. PURPOSE: The aim of this study was to evaluate the effectiveness of the PYTHEAS Your Guided Trajectory (PYGT) navigated angular guidance system for pedicle screw placement, compared with the conventional freehand (FH) technique. MATERIALS AND METHODS: This retrospective single-center study compared two consecutive cohorts of patients undergoing posterior spinal fusion for progressive scoliosis. Screw positioning was assessed using intraoperative 3D imaging according to the Gertzbein and Robbins classification (grades A-E). Cortical breaches were qualitatively analyzed to distinguish screw-pedicle size mismatch from true directional errors. A secondary analysis assessed the influence of surgeon experience (Junior < 5 years vs. Senior > 10 years). RESULTS: 31 patients (mean age 16.3 years) were included, allowing analysis of 635 pedicle screws (317 FH; 318 PYGT). A significantly higher proportion of Grade A screws was observed in the PYGT group compared with the FH group (90.5% vs. 60.6%, p < 0.001). Direction-related malposition rates were markedly reduced with PYGT (2.8% vs. 22.6%, p < 0.001). No Grade D or E screws were observed in the PYGT group. Surgeon experience significantly influenced accuracy in the FH group but had no impact in the PYGT group. CONCLUSION: The PYGT system significantly improved radiographic pedicle screw placement accuracy in posterior spinal surgery and reduced directional errors compared with the freehand technique, particularly in deformity surgery. These findings support the technical effectiveness of the system. Further studies are required to determine whether these improvements translate into clinically meaningful benefits. Direct comparative studies with contemporary navigation and robotic systems are also needed to better define the role of PYGT with regard to radiation exposure, operative time, workflow, cost-effectiveness, and clinical outcomes. LEVEL OF EVIDENCE: IV Retrospective comparative study.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical application of a dual-surface, four-edge 3D-printed pedicle screw guide in adolescent idiopathic scoliosis surgery: a retrospective comparative study.Journal of orthopaedic surgery and research · 2026
- Mind the gap: discrepancies between planned and achieved screw trajectories in 3D-navigated spine surgery.Journal of neurosurgery. Spine · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- Impact of surgeon experience on the safety and accuracy of robot-assisted vs. navigation-guided percutaneous pedicle screw placement: a matched cohort study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- 3D-Printed Guides, Navigation, and Robotic Assistance in Spinal Instrumentation: A Network Meta-Analysis of Pedicle Screw Accuracy and Clinical Outcomes.The spine journal : official journal of the North American Spine Society · 2026