Intraoperative Trajectory Realignment Algorithm for Minimizing Screw Misplacement in Cervical Spinal Fusion.
Pasit Komonsuwan, Jackrit Suthakorn, Shen Treratanakulchai, Sorayouth Chumnanvej
Department of Biomedical Engineering, and Center for Biomedical and Robotics Technology (BART LAB), Faculty of Engineering, Mahidol University, Nakhon Pathom 73170, Thailand. · Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand.
Key points
From the paper's conclusion- This study presents an intraoperative trajectory realignment algorithm that reconciles preoperative computed tomography data with simulated and phantom-derived intraoperative 2-dimensional (2D) projections by integrating forward kinematics, digitally reconstructed radiographs, and optimization-based search strategies.
Abstract
Spinal fusion is a surgical procedure designed to stabilize the spine by connecting vertebrae with screws and rods, where placement accuracy is critical, as even small deviations can cause severe neurovascular complications. The accuracy of traditional preoperative image-based navigation is limited by intraoperative alignment shifts, particularly in the highly mobile cervical spine. This study presents an intraoperative trajectory realignment algorithm that reconciles preoperative computed tomography data with simulated and phantom-derived intraoperative 2-dimensional (2D) projections by integrating forward kinematics, digitally reconstructed radiographs, and optimization-based search strategies. The algorithm was evaluated through computational simulations and physical experiments using a modular 3D-printed cervical spine phantom, with accuracy evaluated through clinical grading and assessment metrics, including entry/end point displacement, angular deviation, and minimum inter-trajectory distance. Results demonstrated high accuracy, with all screws graded as perfectly placed and deviations consistently below clinically relevant thresholds. While these findings confirm the feasibility of this approach under controlled experimental conditions, future validation using cadaveric models and real intraoperative fluoroscopic imaging remains necessary prior to clinical integration.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Augmented reality-enabled image-guided surgical navigation in minimally invasive spine surgery: application beyond screw placement in prone lateral transpsoas interbody fusion-a cadaveric surgical technique study.Journal of spine surgery (Hong Kong) · 2026
- Accuracy of Pedicle Screw Placement at the Cervicothoracic Junction (C7–T2) : A Comparative Study of O-arm Navigation versus C-arm FluoroscopyJournal of Korean Neurosurgical Society · 2026
- The Best of Both Worlds: Combining Freehand and Mobile Intraoperative CT-Navigated Instrumentation in Pediatric Deformity Corrections—A Retrospective Case Series of 31 Consecutive PatientsSurgical Techniques Development · 2026
- Mind the gap: discrepancies between planned and achieved screw trajectories in 3D-navigated spine surgery.Journal of neurosurgery. Spine · 2026
- Robotically equipped 3D hybrid operating room in spine and trauma surgery - updated experience in 359 patients and 2080 screws.Journal of robotic surgery · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026