Accuracy of robot-assisted cortical bone trajectory pedicle screw placement: CT-based retrospective cohort study.
C Minnaert, K VAN DER Donckt, A Depraetere, B Demoor, L Plasschaert, F Plasschaert
Key points
From the paper's conclusion- Robot-assisted pedicle screw placement using CBT demonstrates high accuracy and safety, with absence of clinically relevant medial breaches. These findings support the use of robotic guidance as an effective adjunct in spinal instrumentation.
Abstract
BACKGROUND AND STUDY AIMS: Pedicle screw placement accuracy is critical for safe spinal fixation, and robot- assisted techniques aim to improve precision. This study evaluated the accuracy of robot-assisted posterior pedicle screw placement in the lower thoracic and lumbar spine using a CBT trajectory as well as determine what factors are associated with accuracy of screw placement. MATERIALS AND METHODS: A retrospective single-centre cohort study included 100 consecutive patients undergoing Aposterior spinal instrumentation with pedicle screws between August 2022 and August 2023. Preoperative CT- based planning and robotic guidance (ExcelsiusGPS) were used. Postoperative CT assessed 511 screws using the Gertzbein-Robbins classification, including breach direction. Clinically acceptable placement was defined as grades or B. Interobserver agreement was evaluated using Cohen's kappa and Gwet's AC1. Multivariable analyses were performed using generalized estimating equations and mixed-effects models. RESULTS: Clinically acceptable screw placement exceeded 96% at all spinal levels. Perfect placement ranged from 86.7% to 100%. No clinically relevant (Grade C-E) medial, superior, or inferior breaches were observed; lateral breaches occurred in 1.4%. Interobserver agreement was high (AC1 0.953-0.994). For perfect placement (Grade A), L5 showed higher odds compared to L4. CONCLUSION: Robot-assisted pedicle screw placement using CBT demonstrates high accuracy and safety, with absence of clinically relevant medial breaches. These findings support the use of robotic guidance as an effective adjunct in spinal instrumentation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Axial Convergence in Percutaneous Robotic Pedicle Screw Placement: Mixed-Effects Analysis of 1006 ScrewsSpine Open · 2026
- The accuracy of navigated vs. robot-assisted pedicle screw placement in spine surgery: a retrospective single-centre comparative study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
- Accuracy and influencing factors of robot-assisted sacroiliac screw placement: a comparative study of short versus trans-cortical screws.Journal of robotic surgery · 2026
- The Woodpecker variable-speed drilling protocol for robot-assisted subaxial cervical pedicle screw placement: technique and a consecutive series of 1027 screws.Journal of robotic surgery · 2026
- Robotic-Assisted Cervical Pedicle Screw Placement With Uniform 5.5 mm Rods Crossing the Cervicothoracic Junction: Accuracy and Technical Feasibility.Clinical spine surgery · 2026
- Agreement Between Automated Pedicle Screw Planning and Surgeon-Selected Implant Dimensions in Thoracic and Lumbar Spine Surgery: A Three-Year Single-Center Study.Journal of clinical medicine · 2026